Fast delivery within 72 Hours

B&R 8I84T401850.01P-1

ACOPOSinverter P84, 3x 380 to 480 V, 18.5 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSinverter P84, 3x 380 to 480 V, 18.5 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.

Specification

CEYes
ULcULus E225616 Power conversion equipment
KCYes
Specified on nameplate18.5 kW 25 PS
Mains input voltage3x 380 VAC -15% to 480 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 380 VAC)29.9 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)22 kA
At 400 VAC35.3 A
At 380 VAC41 A
At 480 VAC37.5 A
Power dissipation at nominal load and nominal clock frequency486 W
Integrated EMC filterYes
Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)≤100 m
Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)≤300 m / ≤200 m
Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)≤300 m / ≤200 m
With add-on filter8I0FT072.300-1
At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power)No derating (up to 50°C)
Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com).
Starting at 1000 m above sea level1%, per 100 m
At 460 VAC34 A
Max. transient current for 60 s61.5 A
Max. transient current for 2 s67.7 A
Output frequency range0.5 to 599 Hz
Nominal clock frequency4 kHz
Min.3 mA for 24 VDC
Max.16 kHz
Short-term overload torque (typical value)170% of the motor’s rated torque (typical value at ±10%) for 60 s 220% of the motor’s rated torque (typical value at ±10%) for 2 s
With braking resistorUp to 150% of the rated motor torque
Without braking resistor (typical value)30% of the rated motor torque
Shielded cable100 m
Non-shielded cable150 m
Induction motorFlux vector control (FVC) with encoder (voltage vector) (current vector) Flux vector control (SFVC) without encoder (voltage or current vector) Voltage/frequency ratio – V/f characteristic curve (2 or 5 points) ENA energy adjustment system for asymmetrical loads
Main protective functions of inverterThermal protection against the power stage overheating Protection against: Short circuits between motor phases, mains phase failure, overcurrent between output phases and ground, overvoltages on the DC bus, interruptions in the control loop, exceeding the limit for rotary speed. Safety function for: Overvoltage and undervoltage on the mains supply, mains phase failure on a 3-phase supply
Motor protectionThermal protection integrated in the inverter through continually calculating the l²t value while taking the speed into consideration: -The thermal state of the motor is stored when the frequency inverter is switched off. -The functionality can be adjusted according to the motor type (externally cooled or self-cooling) using an operator interface. Protection against motor phase failures Protection provided by PTC sensors
Integrated dynamic brake transistorsYes
Operating ratio for dynamic brake transistorsThe dynamic brake transistor is designed to tolerate the following values: -Rated motor power continuously -150% of the rated motor power for 60 s
Min. resistance value (external)7 Ω
Input voltage24 VDC (min. 19 V, max. 30 V)
Power consumption30 W
Output voltage 24 VDC24 VDC (min. 21 V, max. 27 V)
Max. output current at 24 VDC200 mA
Output voltage 10.5 VDC10.5 VDC ±5%
Max. output current 10.5 VDC10 mA
Low<5 V
High>15 V
Input - ACOPOSinverterYes
Input - InputNo
Quantity1
Nominal voltage30 VDC / 250 VAC
Response time≤100 ms
Input impedance3.5 kΩ
Input circuitSource or sink
TypeType 3
Sampling time<2 ms ±0.5 ms
Voltage470 Ω
Voltage/Current0 to 10 V or 0 to 20 mA
Resolution10-bit
Current500 Ω
Switching capacityMax. 2 A at 250 VAC or 30 VDC with resistive load
With resistive load (cos φ = 1 and L/R = 0 ms)2 A for 250 VAC or 30 VDC
With inductive load (cos φ = 0.4 and L/R = 7 ms)1.5 A for 250 VAC or 30 VDC
Relay 11 N.O. contact and 1 N.C. contact with a common point
Relay 21 N.O. contact
Response time (max.)<7 ms ±0.5 ms
Output - ACOPOSinverterYes
Output - OutputNo
Output0 to 10 V or 0 to 20 mA
Update time<2 ms ±0.5 ms
Installation elevation above sea level0 to 1000 m
Degree of protection per EN 60529Upper part: IP21 and IP41 Lower part: IP54 (heat sink)
Ambient temperature-10 to 50°C
Max. ambient temperatureUp to 60°C
Relative humidity per IEC 60068-2-35 to 95%, non-condensing No dripping water
Maximum installation elevationUp to 3000 m
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C1 and 3S2
Operating positionVertical installation ±10%
Storage-25 to 70°C
Operation15 g, 11 ms
Width230 mm
Height400 mm
Depth213 mm
Weight9 kg

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8I84T401850.01P-1”

Your email address will not be published. Required fields are marked *