B&R 8I74T401100.01P-1
ACOPOSinverter P74, 3x 380 to 500 V,
11 kW, integrated EMC filter and
brake chopper,
shield plate included in delivery,
POWERLINK interfaceFor revision information, see the following model numbers: 8I…
Shipping & Delivery
- 
Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery
 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year
 
- 
Free 30-Day returns
 
Description
ACOPOSinverter P74, 3x 380 to 500 V,
11 kW, integrated EMC filter and
brake chopper,
shield plate included in delivery,
POWERLINK interfaceFor revision information, see the following model numbers: 8I74T401100.010-18I0IF108.400-1
Specification
| CE | 
 Yes  | 
|---|---|
| UL | 
 UL E225616Power conversion equipment  | 
| KC | 
 Yes  | 
| Specified on nameplate | 
 11 kW (15 HP)  | 
| Mains input voltage | 
 3x 380 VAC -15% to 500 VAC +10%  | 
| Frequency | 
 50 to 60 Hz ±5%  | 
| Apparent power (at 500 VAC) | 
 22.2 kVA  | 
| Max. assumed short-circuit current (Isc)(short-circuit current at connection point) | 
 22 kA  | 
| Inrush current | 
 Max. 36.7 A  | 
| At 380 VAC | 
 36.6 A  | 
| At 500 VAC | 
 25.6 A  | 
| Power dissipation at nominal load and nominal clock frequency | 
 403 W  | 
| Integrated EMC filter | 
 Yes  | 
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | 
 C1 level of 2 to 16 kHz with 5 m cableC1 level of 2 to 8 kHz with 10 m cableC1 level of 2 to 4 kHz with 20 m cable  | 
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | 
 C2 level of 2 to 16 kHz with 50 m cableC2 level of 2 to 12 kHz with 100 m cable  | 
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) | 
 50 m  | 
| With add-on filter | 
 8I0FT049.200-1  | 
| Nominal output current | 
 27.7 A  | 
| At nominal clock frequency (4 kHz) | 
 No derating (up to 50°C)  | 
| Other clock frequencies | 
 The derating curves are included in the installation instructions, which can be downloaded from http://www.br-automation.com.  | 
| Starting at 1000 m above sea level | 
 1%, per 100 m  | 
| Max. transient current for 60 s | 
 41.6 A  | 
| Max. transient current for 2 s | 
 45.7 A  | 
| Output frequency range | 
 0.1 to 599 Hz  | 
| Nominal clock frequency | 
 4 kHz  | 
| Min. | 
 2 kHz  | 
| Max. | 
 16 kHz  | 
| With braking resistor | 
 Up to 170% of the nominal motor torque  | 
| Shielded cable | 
 50 m  | 
| Non-shielded cable | 
 100 m  | 
| Induction motor | 
 Sensorless vector control:1. With V/f characteristic curve for constant torque→ Default profile2. With V/f characteristic curve for quadratically increasing torque→ Energy-saving profile, e.g. for fans and pumpsSensorless slip control:1. With V/f characteristic curve for constant torque→ Default profile2. With V/f characteristic curve for constant torque (6 f ranges)→ Profile for individual special applications3. With V/f characteristic curve for quadratically increasing torque→ Energy-saving profile, e.g. for fans and pumps  | 
| Synchronous motor | 
 Sensorless vector control:1. With V/f characteristic curve for constant torque→ Default profile  | 
| Main protective functions of inverter | 
 Thermal protection against power stage overheatingProtection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply  | 
| Integrated dynamic brake transistors | 
 Yes  | 
| Min. resistance value (external) | 
 16 Ω  | 
| Input voltage | 
 24 VDC (-15%/+20%)  | 
| Current | 
 800 Ω  | 
| Output voltage 24 VDC | 
 24 VDC (-15%/+20%)  | 
| Max. output current at 24 VDC | 
 100 mA  | 
| Output voltage 10 VDC | 
 10 VDC (-0%/+10%)  | 
| Max. output current at 10 VDC | 
 10 mA  | 
| Type | 
 Type 2  | 
| Quantity | 
 1  | 
| Nominal voltage | 
 30 VDC / 250 VAC  | 
| Input circuit | 
 Sink  | 
| Current consumption | 
 16 mA  | 
| Input - ACOPOSinverter | 
 Yes  | 
| Input - Input | 
 No  | 
| Sampling time | 
 2 ms  | 
| Input impedance | 
 1.5 kΩ  | 
| Max. input frequency | 
 20 kHz  | 
| Low | 
 <2 V  | 
| High | 
 >17 V  | 
| Voltage | 
 470 Ω  | 
| Resolution | 
 10-bit  | 
| Max. voltage | 
 30 VDC  | 
| Output circuit | 
 Source or sink  | 
| Max. current | 
 100 mA  | 
| Switching capacity | 
 R1, with resistive load (cos phi = 1): 3 A at 250 VAC, R1, with resistive load (cos phi = 1): 4 A at 30 VDC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 250 VAC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 30 VDC, R2 with resistive load (cos phi = 1): 5 A at 250 VAC, R2 with resistive load (cos phi = 1): 5 A at 30 VDC  | 
| Relay 1 | 
 1 changeover contact  | 
| Relay 2 | 
 1 normally open contact  | 
| Output - ACOPOSinverter | 
 Yes  | 
| Output - Output | 
 No  | 
| Response time (max.) | 
 2 ms  | 
| Output | 
 0 to 10 V or 0 to 20 mA  | 
| Update time | 
 2 ms  | 
| Degree of protection per EN 60529 | 
 IP20  | 
| Relative humidity per IEC 60068-2-3 | 
 5 to 95%. non-condensingNo dripping water  | 
| Maximum installation elevation | 
 Up to 2000 m  | 
| Max. pollution degree per IEC/EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Ambient conditions per IEC 60721-3-3 | 
 Class 3C3 and 3S3  | 
| Operating position | 
 Vertical mounting orientation ±10%  | 
| Operation | 
 -10 to 50°C without derating50 to 60°C with derating  | 
| Storage | 
 -25 to 70°C  | 
| Max. vibration resistance | 
 1 gn 13 to 200 Hz EN/IEC 60068-2-61.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6  | 
| Width | 
 180 mm  | 
| Height | 
 404 mm  | 
| Height without shield plate | 
 330 mm  | 
| Depth | 
 232 mm  | 
| Weight | 
 6.750 kg  | 
	
	
				
				
		
		
		
		
		
		
		