B&R 8I74S200055.00-000

ACOPOSinverter P74new, 1x 200-240 V, 0.55 kW, integrated EMC filter and brake chopper, shield plate included in delivery.

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSinverter P74new, 1x 200-240 V, 0.55 kW, integrated EMC filter and brake chopper, shield plate included in delivery.

Specification

CEYes
ULUL E225616 Power conversion equipment
CSACSA E272421 Industrial control equipment
Specified on nameplate0.55 kW (0.75 HP)
Mains input voltage1x 200 VAC -15% to 240 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 240 VAC)1.6 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)1 kA
Inrush currentMax. 9.6 A
At 200 VAC7.9 A
At 240 VAC6.7 A
Power dissipation at nominal load and nominal clock frequency42 W
Integrated EMC filterYes
Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)C1 level of 2 to 16 kHz with 20 m cable
Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level of 2 to 6 kHz with 50 m cable C2 level at 2 kHz with 100 m cable
Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)50 m
With add-on filter8I0FS009.200-2
Nominal output current3.7 A
At nominal clock frequency (4 kHz)No derating (up to 50°C)
Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Starting at 1000 m above sea level1%, per 100 m
Max. transient current for 60 s5.6 A
Max. transient current for 2 s6.1 A
Output frequency range0.1 to 599 Hz
Nominal clock frequency4 kHz
Min.2 kHz
Max.16 kHz
With braking resistorUp to 170% of the nominal motor torque
Shielded cable50 m
Non-shielded cable100 m
Induction motorSensorless vector control: 1. With V/f characteristic curve for constant torque → Default profile 2. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps Sensorless slip control: 1. With V/f characteristic curve for constant torque → Default profile 2. With V/f characteristic curve for constant torque (6 f ranges) → Profile for individual special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps
Synchronous motorSensorless vector control: 1. With V/f characteristic curve for constant torque → Default profile
Main protective functions of inverterThermal protection against power stage overheating Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply
Integrated dynamic brake transistorsYes
Min. resistance value (external)40 Ω
Input voltage24 VDC (-15%/+20%)
Current800 Ω
Output voltage 24 VDC24 VDC (-15%/+20%)
Max. output current at 24 VDC100 mA
Output voltage 10 VDC10 VDC (-0%/+10%)
Max. output current at 10 VDC10 mA
TypeType 2
Quantity1
Nominal voltage30 VDC / 250 VAC
Input circuitSink
Current consumption16 mA
Input - ACOPOSinverterYes
Input - InputNo
Sampling time2 ms
Input impedance1.5 kΩ
Max. input frequency20 kHz
Low<2 V
High>17 V
Voltage470 Ω
Resolution10-bit
Max. voltage30 VDC
Output circuitSource or sink
Max. current100 mA
Switching capacityR1, with resistive load (cos phi = 1): 3 A at 250 VAC, R1, with resistive load (cos phi = 1): 4 A at 30 VDC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 250 VAC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 30 VDC, R2 with resistive load (cos phi = 1): 5 A at 250 VAC, R2 with resistive load (cos phi = 1): 5 A at 30 VDC
Relay 11 changeover contact
Relay 21 normally open contact
Output - ACOPOSinverterYes
Output - OutputNo
Response time (max.)2 ms
Output0 to 10 V or 0 to 20 mA
Update time2 ms
Degree of protection per EN 60529IP20
Relative humidity per IEC 60068-2-35 to 95%. non-condensing No dripping water
Maximum installation elevationUp to 2000 m
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S3
Operating positionVertical mounting orientation ±10%
Operation-10 to 50°C without derating 50 to 60°C with derating
Storage-25 to 70°C
Max. vibration resistance1 gn 13 to 200 Hz EN/IEC 60068-2-6 1.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6
Width45 mm
Height317 mm
Depth245 mm
Weight1.646 kg