Fast delivery within 72 Hours
B&R 8I74S200018.01P-1
ACOPOSinverter P74, 1x 200 to 240 V,
0.18 kW, integrated EMC filter and
brake chopper,
shield plate included in delivery,
POWERLINK interfaceFor revision information, see the following model numbers:8…
Shipping & Delivery
- 
Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery
 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year
 
- 
Free 30-Day returns
 
Description
ACOPOSinverter P74, 1x 200 to 240 V,
0.18 kW, integrated EMC filter and
brake chopper,
shield plate included in delivery,
POWERLINK interfaceFor revision information, see the following model numbers:8I74S200018.010-18I0IF108.400-1
Specification
| CE | 
 Yes  | 
|---|---|
| UL | 
 UL E225616  | 
| KC | 
 Yes  | 
| Specified on nameplate | 
 0.18 kW (0.25 HP)  | 
| Mains input voltage | 
 1x 200 VAC -15% to 240 VAC +10%  | 
| Frequency | 
 50 to 60 Hz ±5%  | 
| Apparent power (at 240 VAC) | 
 0.7 kVA  | 
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point) | 
 1 kA  | 
| Inrush current | 
 Max. 9.6 A  | 
| At 200 VAC | 
 3.4 A  | 
| At 240 VAC | 
 2.8 A  | 
| Power dissipation at nominal load and nominal clock frequency | 
 25 W  | 
| Integrated EMC filter | 
 Yes  | 
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | 
 C1 level of 2 to 16 kHz with 20 m cable  | 
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | 
 C2 level of 2 to 6 kHz with 50 m cable  | 
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) | 
 50 m  | 
| With add-on filter | 
 8I0FS009.200-2  | 
| Nominal output current | 
 1.5 A  | 
| At nominal clock frequency (4 kHz) | 
 No derating (up to 50°C)  | 
| Other clock frequencies | 
 The derating curves are included in the installation instructions, which can be downloaded from http://www.br-automation.com.  | 
| Starting at 1000 m above sea level | 
 1%, per 100 m  | 
| Max. transient current for 60 s | 
 2.3 A  | 
| Max. transient current for 2 s | 
 2.5 A  | 
| Output frequency range | 
 0.1 to 599 Hz  | 
| Nominal clock frequency | 
 4 kHz  | 
| Min. | 
 2 kHz  | 
| Max. | 
 16 kHz  | 
| With braking resistor | 
 Up to 170% of the nominal motor torque  | 
| Shielded cable | 
 50 m  | 
| Non-shielded cable | 
 100 m  | 
| Induction motor | 
 Sensorless vector control:  | 
| Synchronous motor | 
 Sensorless vector control:  | 
| Main protective functions of inverter | 
 Thermal protection against power stage overheating  | 
| Integrated dynamic brake transistors | 
 Yes  | 
| Min. resistance value (external) | 
 40 Ω  | 
| Input voltage | 
 24 VDC (-15%/+20%)  | 
| Current | 
 800 Ω  | 
| Output voltage 24 VDC | 
 24 VDC (-15%/+20%)  | 
| Max. output current at 24 VDC | 
 100 mA  | 
| Output voltage 10 VDC | 
 10 VDC (-0%/+10%)  | 
| Max. output current at 10 VDC | 
 10 mA  | 
| Type | 
 Type 2  | 
| Quantity | 
 1  | 
| Nominal voltage | 
 30 VDC / 250 VAC  | 
| Input circuit | 
 Sink  | 
| Current consumption | 
 16 mA  | 
| Input - ACOPOSinverter | 
 Yes  | 
| Input - Input | 
 No  | 
| Sampling time | 
 2 ms  | 
| Input impedance | 
 1.5 kΩ  | 
| Max. input frequency | 
 20 kHz  | 
| Low | 
 <2 V  | 
| High | 
 >17 V  | 
| Voltage | 
 470 Ω  | 
| Resolution | 
 10-bit  | 
| Max. voltage | 
 30 VDC  | 
| Output circuit | 
 Source or sink  | 
| Max. current | 
 100 mA  | 
| Switching capacity | 
 R1, with resistive load (cos phi = 1): 3 A at 250 VAC,  | 
| Relay 1 | 
 1 changeover contact  | 
| Relay 2 | 
 1 normally open contact  | 
| Output - ACOPOSinverter | 
 Yes  | 
| Output - Output | 
 No  | 
| Response time (max.) | 
 2 ms  | 
| Output | 
 0 to 10 V or 0 to 20 mA  | 
| Update time | 
 2 ms  | 
| Degree of protection per EN 60529 | 
 IP20  | 
| Relative humidity per IEC 60068-2-3 | 
 5 to 95%. non-condensing  | 
| Maximum installation elevation | 
 Up to 2000 m  | 
| Max. pollution degree per IEC/EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Ambient conditions per IEC 60721-3-3 | 
 Class 3C3 and 3S3  | 
| Operating position | 
 Vertical mounting orientation ±10%  | 
| Operation | 
 -10 to 50°C without derating  | 
| Storage | 
 -25 to 70°C  | 
| Max. vibration resistance | 
 1 gn 13 to 200 Hz EN/IEC 60068-2-6  | 
| Width | 
 45 mm  | 
| Height | 
 317 mm  | 
| Depth | 
 245 mm  | 
| Weight | 
 1.59 kg  | 
	
	
				
				
		
		
		
		
		
		
		
Reviews