B&R 8I66T200075.00-000
Base device for ACOPOSinverter P66 and P64new, 3 x 200 to 240 V, 0.75 kW, integrated brake chopperOrder number – ACOPOSinverter P66: 8I66T200075.0P-000: Inverter with POWERLINK communication card8I66T…
Shipping & Delivery
- 
Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery
 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year
 
- 
Free 30-Day returns
 
Description
Base device for ACOPOSinverter P66 and P64new, 3 x 200 to 240 V, 0.75 kW, integrated brake chopperOrder number – ACOPOSinverter P66: 8I66T200075.0P-000: Inverter with POWERLINK communication card8I66T200075.0X-000: Inverter with X2X Link communication card8I66T200075.0C-000: Inverter with integrated CANopen interface Order number – ACOPOSinverter P64new: 8I64T200075.0X-000: Inverter with X2X Link communication card
Specification
| CE | 
 Yes  | 
|---|---|
| UKCA | 
 Yes  | 
| CRA (Cyber Resilience Act) | 
 In preparation  | 
| UL | 
 cULus E225616  | 
| Specified on nameplate | 
 0.75 kW (1 HP)  | 
| Mains input voltage | 
 3x 200 VAC -15% to 240 VAC +10%  | 
| Frequency | 
 50 to 60 Hz ±5%  | 
| Apparent power (at 240 VAC) | 
 2 kVA  | 
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point) | 
 5 kA  | 
| Inrush current | 
 Max. 9.6 A  | 
| At 200 VAC | 
 5.6 A  | 
| At 240 VAC | 
 4.7 A  | 
| Power dissipation at nominal load and nominal clock frequency | 
 49 W  | 
| Integrated EMC filter | 
 No  | 
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | 
 1 m  | 
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | 
 5 m  | 
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) | 
 5 m  | 
| Nominal output current | 
 4.8 A  | 
| At nominal clock frequency (4 kHz) | 
 No derating (up to 50°C)  | 
| Other clock frequencies | 
 The derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com).  | 
| Starting at 1000 m above sea level | 
 1%, per 100 m  | 
| Max. transient current for 60 s | 
 7.2 A  | 
| Output frequency range | 
 0.1 to 599 Hz  | 
| Nominal clock frequency | 
 4 kHz  | 
| Min. | 
 2 kHz  | 
| Max. | 
 16 kHz  | 
| With braking resistor | 
 Up to 170% of the rated motor torque  | 
| Shielded cable | 
 50 m  | 
| Non-shielded cable | 
 100 m  | 
| Induction motor | 
 Sensorless vector control:  | 
| Synchronous motor | 
 Sensorless vector control:  | 
| Main protective functions of inverter | 
 Thermal protection against power stage overheating  | 
| Integrated dynamic brake transistors | 
 Yes  | 
| Min. resistance value (external) | 
 40 Ω  | 
| Input voltage | 
 24 VDC (-15%/+20%)  | 
| Current | 
 800 Ω  | 
| Output voltage 24 VDC | 
 24 VDC (-15%/+20%)  | 
| Max. output current at 24 VDC | 
 100 mA  | 
| Output voltage 10 VDC | 
 10 VDC (-0%/+10%)  | 
| Max. output current at 10 VDC | 
 10 mA  | 
| Type | 
 Type 3  | 
| Quantity | 
 1  | 
| Nominal voltage | 
 30 VDC / 250 VAC  | 
| Input circuit | 
 Source or sink  | 
| Switching threshold | 
 Sink: >19 V (position 0), <13 V (position 1)  | 
| Input - ACOPOSinverter | 
 Yes  | 
| Input - Input | 
 No  | 
| Sampling time | 
 2 ms  | 
| Max. input frequency | 
 20 kHz  | 
| Input impedance | 
 1.5 kΩ  | 
| Current consumption | 
 16 mA  | 
| Nonlinearity | 
 ±0.3%  | 
| Basic accuracy | 
 At 25°C: ±1%  | 
| Voltage | 
 470 Ω  | 
| Resolution | 
 10-bit  | 
| Max. voltage | 
 30 VDC  | 
| Output circuit | 
 Source or sink  | 
| Max. current | 
 100 mA  | 
| Switching current range | 
 Min. switching current: 5 mA at 24 VDC  | 
| Relay 1 | 
 1 changeover contact  | 
| Relay 2 | 
 1 normally open contact  | 
| Output - ACOPOSinverter | 
 Yes  | 
| Output - Output | 
 No  | 
| Response time (max.) | 
 2 ms  | 
| Output | 
 0 to 10 V or 0 to 20 mA  | 
| Update time | 
 2 ms  | 
| Power dissipation relative to continuous apparent power | 
 IE2 (10, 25): 1.2% (3x 200 VAC), 1.1% (3x 240 VAC)  | 
| Nominal losses in standby mode | 
 6 W  | 
| Degree of protection per EN 61800-5-1 | 
 IP20  | 
| Relative humidity per IEC 60068-2-3 | 
 5 to 95%, non-condensing  | 
| Maximum installation elevation | 
 ≤1000 m without derating  | 
| Max. pollution degree per IEC/EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Ambient conditions per IEC 60721-3-3 | 
 Class 3C3 and 3S2  | 
| Operating position | 
 Vertical mounting orientation ±10°  | 
| Operation | 
 -10 to 50°C without derating  | 
| Storage | 
 -25 to 70°C  | 
| Max. vibration resistance | 
 1 gn 13 to 200 Hz EN/IEC 60068-2-6  | 
| Width | 
 72 mm  | 
| Height | 
 188 mm  | 
| Height without shield plate | 
 143 mm  | 
| Depth | 
 138 mm  | 
| Weight | 
 1 kg  | 
	
	
				
				
		
		
		
		
		
		
		