Current transformer terminal block, 2007 Series, operating toolOur current transformer terminal block (item number 2007-8876) ensures effortless electrical installations. Ensure that the strip lengths are between 13 and 15 mm  when connecting conductors to this current transformer terminal block. This product features conductor terminals and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® technology provides a universal connection solution for any type of conductor. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. Depending on the type of conductor, this current transformer terminal block is suitable for conductor cross sections ranging from 0.5 mm² to 10 mm².

Specification

Electrical data - Ratings per IEC/EN

Nominal voltage (III/3)500 V
Rated impulse withstand voltage (III / 3)6 kV
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Number of levels1

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper, Copper
Nominal cross-section6 mm² / 10 AWG
Solid conductor0.5 … 10 mm² / 20 … 8 AWG
Solid conductor; push-in termination1 … 10 mm² / 14 … 8 AWG
Fine-stranded conductor0.5 … 10 mm² / 20 … 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 6 mm² / 20 … 10 AWG
Fine-stranded conductor; with uninsulated ferrule1.5 … 6 mm² / 16 … 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 … 6 mm² / 16 … 10 AWG
Strip length13 … 15 mm / 0.51 … 0.59 inches
Wiring directionFront-entry wiring

Physical data

Width85 mm / 3.346 inches
Height99.6 mm / 3.921 inches
Depth from upper-edge of DIN-rail65.3 mm / 2.571 inches
Module width8 mm / 0.315 inches

Mechanical data

Mounting typeDIN-35 rail, DIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colormulti-colored
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load3.527 MJ
Weight205 g
Test socket colororange

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

Product Group22 (TOPJOB S)
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4050821771678
Customs tariff number85369010000

Product Classification

UNSPSC39121410
eCl@ss 10.027-14-11-47
eCl@ss 9.027-14-11-47
ETIM 9.0EC000276
ETIM 10.0EC000276
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.7439-92-1
REACH Candidate List SubstanceLead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)c2cf3322-fccd-4201-97bf-bd1dbc91a9d4
SCIP notification number (Belgium)df0d5c51-1e75-4403-b4dd-ba33ad0d4c9b
SCIP notification number (Bulgaria)a1ea7400-9546-43b0-9cb2-fdaca499c841
SCIP notification number (Czech Republic)32530725-558c-472b-9a14-013c936d81b2
SCIP notification number (Denmark)1317d9e5-ddd0-4f1d-b910-87615d9cc789
SCIP notification number (Finland)a44cc3df-0bc6-414a-9788-6ce0fcb3e35f
SCIP notification number (France)53c43239-dd10-405b-bd3a-7c679b5f1783
SCIP notification number (Germany)a679ffd2-9453-4083-aa8a-8b22ceb19783
SCIP notification number (Hungary)8a92e63e-9472-43e2-be7c-b6e554d7d8c2
SCIP notification number (Italy)f8904cdc-0e77-4df1-947f-2d6225819a30
SCIP notification number (Netherlands)e20ec976-31ac-4d97-ae16-fff9399fe5b9
SCIP notification number (Poland)fe79e07f-2582-43af-953c-47ac20bee156
SCIP notification number (Romania)ee0d896a-e526-4bb2-80d7-1917cda6f67b
SCIP notification number (Sweden)621f2e21-65df-4005-a33f-edee6570de9e

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2007-8876”

Your email address will not be published. Required fields are marked *