Fast delivery within 72 Hours

Wago 2007-8804

Through terminal block, 2007 Series, Push-in CAGE CLAMP®This through terminal block (item number 2007-8804) is designed for simple and secure connections. Strip lengths must be between 13 and 15 mm  w…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Through terminal block, 2007 Series, Push-in CAGE CLAMP®This through terminal block (item number 2007-8804) is designed for simple and secure connections. Strip lengths must be between 13 and 15 mm  when connecting conductors to this through terminal block. Featuring conductor terminals along with Push-in CAGE CLAMP®, this product outperforms the competition. Our Push-in CAGE CLAMP® is a universal, maintenance-free connection solution for all conductor types, offering a key advantage: both solid and fine-stranded conductors with ferrules can be directly inserted without the need for tools or any preparation, such as crimping the ferrule. Depending on the conductor type, this through terminal block is designed for conductor cross sections ranging from 0.5 mm² to 10 mm².

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60664-1
Nominal voltage (III/3)500 V
Rated impulse withstand voltage (III / 3)6 kV
Rated current30 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage500 V
Rated impulse withstand voltage6 kV
Rated current30 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)300 V
Rated current UL (Use Group B)30 A
Rated voltage UL (Use Group C)300 V
Rated current UL (Use Group C)30 A
Rated voltage UL (Use Group D)300 V
Rated current UL (Use Group D)10 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage300 V / 300 V / 300 V
Rated current30 A / 30 A / 10 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)300 V
Rated current CSA (Use Group B)30 A
Rated voltage CSA (Use Group C)300 V
Rated current CSA (Use Group C)30 A
Rated voltage CSA (Use Group D)300 V
Rated current CSA (Use Group D)10 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage300 V / 300 V / 300 V
Rated current30 A / 30 A / 10 A

Electrical data - Power Loss

Power loss, per pole (potential)0.702 W
Rated current I<sub>N</sub> for power loss specification30 A
Resistance value for specified, current-dependent power loss0.001 Ω

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units2
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section6 mm² / 10 AWG
Solid conductor0.5 … 10 mm² / 20 … 8 AWG
Solid conductor; push-in termination1 … 10 mm² / 14 … 8 AWG
Fine-stranded conductor0.5 … 10 mm² / 20 … 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 6 mm² / 20 … 10 AWG
Fine-stranded conductor; with uninsulated ferrule1.5 … 6 mm² / 16 … 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 … 6 mm² / 16 … 10 AWG
Strip length13 … 15 mm / 0.51 … 0.59 inches
Wiring directionFront-entry wiring

Physical data

Width8 mm / 0.315 inches
Height99.6 mm / 3.921 inches
Depth from upper-edge of DIN-rail46.8 mm / 1.843 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colorblue
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.387 MJ
Weight21.9 g
Test socket colororange

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

PU (SPU)20 pcs
Packaging typebox
Country of originCN
GTIN4055143300285
Customs tariff number85369010000

Product Classification

UNSPSC39121410
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.7439-92-1
REACH Candidate List SubstanceLead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)f054a96e-b7df-4515-a5fc-d3750186064c
SCIP notification number (Belgium)355615ac-9ae0-4344-b217-ba2182860087
SCIP notification number (Bulgaria)b791c995-6634-4ba2-aaa3-96caa33d2bb7
SCIP notification number (Czech Republic)45223efb-59c8-4127-920e-8e30fb70ebb6
SCIP notification number (Denmark)342eb0d9-bd6d-4b4c-92b6-4cd59f754ffe
SCIP notification number (Finland)f9813f4a-5b26-4d2b-86ce-f1a07c8fd110
SCIP notification number (France)f4cbdd21-38a6-4f68-aba2-9db91fdcf487
SCIP notification number (Germany)de9ca837-15ae-40ee-b1cd-e657c0cd7965
SCIP notification number (Hungary)5cc1332a-128b-4a2b-8007-c7cac0206d5e
SCIP notification number (Italy)505c92d4-a356-48a3-88a4-6a865830bc2f
SCIP notification number (Netherlands)cd8be6be-047e-4d9d-a405-fb4a8e2e6fdc
SCIP notification number (Poland)17a3edc6-d03d-4524-857d-0a116a831e08
SCIP notification number (Romania)fce9afda-ff5e-4a73-9d5e-e1ab895cd0ef
SCIP notification number (Sweden)c21c5bcb-d713-451b-b2ae-49bf0c2fee06

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2007-8804”