Fast delivery within 72 Hours
B&R 8EI024HCSS0.XXXX-1
ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting
Shipping & Delivery
- 
Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery
 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year
 
- 
Free 30-Day returns
 
Description
ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting
Specification
| Dynamic node allocation (DNA) | 
 Yes  | 
|---|---|
| Slots for plug-in modules | 
 1  | 
| CE | 
 Yes  | 
| UKCA | 
 Yes  | 
| CRA (Cyber Resilience Act) | 
 In preparation  | 
| UL | 
 cULus E225616  | 
| Network configurations | 
 TT, TN, TN-S, TN-C-S, IT  | 
| Mains input voltage | 
 3x 200 VAC to 480 VAC ±10%  | 
| Frequency | 
 50 / 60 Hz ±4%  | 
| Installed load | 
 Max. 18.7 kVA  | 
| Inrush current | 
 Max. 100 A  | 
| Switch-on interval | 
 120 s  | 
| Integrated line filter per EN 61800-3, category C3 | 
 No  | 
| With wire end sleeve | 
 0.25 to 2.5 mm²  | 
| UL/C-UL-US | 
 26 to 12 AWG  | 
| CSA | 
 26 to 12 AWG  | 
| Power dissipation at device nominal power without braking resistor | 
 [81 W + 9.7 V * I + 8.4 W/kW * Pout + 0.25 Ω * I2BR + PVSLOT] * 1.1  | 
| Power dissipation remaining in the control cabinet | 
 Pv_inside = 0.510 * Pv + 1.624 * (T_amb – T_inside)  | 
| Max. line length | 
 100 m  | 
| Continuous power | 
 4 kW  | 
| Mains input voltage <3x 400 VAC | 
 10 kW * (Mains input voltage [V] / 400 V)  | 
| DC bus capacitance | 
 1680 µF  | 
| With wire end sleeves | 
 0.25 to 4 mm²  | 
| Input voltage | 
 24 VDC ±25%  | 
| Input capacitance | 
 5500 ÎĽF  | 
| Current consumption | 
 2 A + Current for motor holding brake  | 
| Quantity | 
 1  | 
| Continuous power per motor connection | 
 10 kW  | 
| Continuous current per motor connection | 
 24 Aeff  | 
| SIL 2 / PL d / Cat. 3 | 
 Hardware upgrade 1.10.2.x: 7.489 A  | 
| SIL 2 / PL d / Cat. 2 | 
 2.498 A  | 
| Switching frequency 5 kHz | 
 75 m  | 
| Switching frequency 10 kHz | 
 35 m  | 
| Switching frequency 20 kHz | 
 20 m  | 
| Starting at 500 m above sea level | 
 2.4 Aeff per 1000 m  | 
| Peak current per motor connection | 
 60 Aeff  | 
| Peak power output | 
 45 kW  | 
| Nominal switching frequency | 
 5 kHz  | 
| Possible switching frequencies | 
 2.5 / 5 / 10 / 20 kHz  | 
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | 
 Limit value curve A  | 
| Overload protection | 
 No  | 
| Short-circuit and ground fault protection | 
 Short-circuit protection: Yes  | 
| Max. output frequency | 
 598 Hz  | 
| U, V, W, PE | 
 Connector  | 
| Shield connection | 
 Yes  | 
| Output voltage | 
 Configurable  | 
| Continuous current per connection | 
 6.5 A  | 
| Max. internal resistance | 
 0.25 Ω  | 
| Extinction potential | 
 Approx. 30 V  | 
| Max. extinction energy per switching operation | 
 15 Ws  | 
| Max. switching frequency | 
 0.5 Hz  | 
| Overload and short-circuit protection | 
 Yes  | 
| Open-circuit monitoring | 
 Yes  | 
| Undervoltage monitoring | 
 Yes  | 
| Response threshold for open-circuit monitoring | 
 Approx. 120 mA  | 
| Response threshold for undervoltage monitoring | 
 Approx. 23 V  | 
| Max. breaking current SBC | 
 200 mA  | 
| Minimum braking resistance (ext.) | 
 13 Ω  | 
| Type | 
 Digital multi-encoder interface, configurable  | 
| Variant | 
 2x RJ45, shielded, 2-port hub  | 
| Line length | 
 Max. 100 m between 2 stations (segment length)  | 
| Transfer rate | 
 100 Mbit/s  | 
| Connections | 
 8-pin female Mini I/O connector  | 
| Status indicators | 
 None  | 
| Encoder - ACOPOS P3 | 
 No  | 
| Max. encoder cable length | 
 75 m  | 
| Load capacity | 
 Max. 300 mA  | 
| Sense lines | 
 2, compensation of max. 2x 0.7 V  | 
| Short-circuit proof | 
 Yes  | 
| Overload-proof | 
 Yes  | 
| Signal transmission | 
 RS485  | 
| Data transfer rate | 
 Depends on the configured encoder type  | 
| Minimum | 
 -25°C  | 
| Maximum | 
 55°C  | 
| Max. power consumption per encoder interface | 
 PENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W  | 
| Circuit | 
 Sink  | 
| Input - ACOPOS P3 | 
 Yes  | 
| Input - Input | 
 Yes  | 
| Nominal | 
 5 to 40°C  | 
| Low | 
 <5 V  | 
| High | 
 >15 V  | 
| Input current at nominal voltage | 
 7 mA  | 
| Rising edge | 
 <51 µs  | 
| Falling edge | 
 <52 µs  | 
| Modulation compared to ground potential | 
 Max. ±38 V  | 
| Resistance range | 
 500 Ω to 5 kΩ  | 
| Mapp Motion | 
 5.05.0 and higher  | 
| ACP10/ARNC0 | 
 5.03.0 and higher  | 
| Power dissipation relative to continuous apparent power | 
 IE2 (10,25) 1.2%  | 
| Nominal losses in standby mode | 
 15.8 W  | 
| Hanging vertically | 
 Yes  | 
| Horizontal, face up | 
 No  | 
| Standing horizontally | 
 No  | 
| Pollution degree per EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Overvoltage category per EN 61800-5-1 | 
 III  | 
| Degree of protection per EN 60529 | 
 IP20  | 
| Storage | 
 5 to 95%  | 
| Transport | 
 95% at 40°C  | 
| Operation | 
 5 to 85 %, non-condensing  | 
| Width | 
 133 mm  | 
| Height | 
 374 mm  | 
| Depth | 
 264.50 mm (with 8EXA front cover: 267 mm)  | 
| Cold plate | 
 281.5 mm (with 8EXA front cover: 284 mm)  | 
| Pass-through mounting | 
 277.5 mm (with 8EXA front cover: 280 mm)  | 
| Weight | 
 9.4 kg  | 
	
	
				
				
		
		
		
		
		
		
		
Reviews
Clear filtersThere are no reviews yet.