Fast delivery within 72 Hours

Wago 2006-1304/984-000

Through terminal block, 2006 Series, blueOur through terminal block (item number 2006-1304/984-000) makes connections quick and easy. Ensure that the strip lengths are between 13 and 15 mm  when conne…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Through terminal block, 2006 Series, blueOur through terminal block (item number 2006-1304/984-000) makes connections quick and easy. Ensure that the strip lengths are between 13 and 15 mm  when connecting conductors to this through terminal block. Whether in industrial or building applications, our rail-mount through terminal blocks are the perfect solution to quickly and securely connect electrical conductors. Depending on the variant, you can use them for either typical through-wiring or potential distribution. Featuring conductor terminals along with Push-in CAGE CLAMP®, this connector delivers reliable performance. Our Push-in CAGE CLAMP® is a universal, maintenance-free connection solution for all conductor types, offering a key advantage: It allows direct insertion of both solid and fine-stranded conductors with ferrules without needing tools. No preparation is required; for example, crimping the conductor’s ferrule is not necessary. The item’s dimensions are (7.5 x 73.3 x 39.5) mm (width x height x depth). This through terminal block is suitable for conductor cross sections ranging from 0.5 mm² to 10 mm².This through rail-mount terminal block is operated with an operating tool. Our TOPJOB® S rail-mount terminal blocks are perfect for a wide range of industrial applications and modern building installations thanks to the secure electrical connections they provide. You can work anywhere in the world and on any application with just a single rail-mount terminal block system. This product is designed for specific Ex applications (please refer to the product datasheet).

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-1
Nominal voltage (III/3)1000 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current41 A
Current at conductor cross-section (max.) mm²57 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Rated impulse withstand voltage8 kV
Current at conductor cross-section (max.) mm²57 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)600 V
Rated current UL (Use Group B)50 A
Rated voltage UL (Use Group C)600 V
Rated current UL (Use Group C)50 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current50 A / 50 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)600 V
Rated current CSA (Use Group B)50 A
Rated voltage CSA (Use Group C)600 V
Rated current CSA (Use Group C)50 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current50 A / 50 A

Electrical data - Ex information

Reference to hazardous areasSee application instructions in section “Knowledge and Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Ratings perATEX: PTB 05 ATEX 1030 U / IECEx: PTB 05.0014U (Ex eb IIC Gb)
Rated voltage EN (Ex e II)550 V
Rated current (Ex e II)36 A
Rated current (Ex e II) with jumper33 A

Electrical data - Power Loss

Power loss, per pole (potential)1.311 W
Rated current I<sub>N</sub> for power loss specification41 A
Resistance value for specified, current-dependent power loss0.001 Ω

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units3
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section6 mm²
Solid conductor0.5 … 10 mm² / 20 … 8 AWG
Solid conductor; push-in termination2.5 … 10 mm² / 14 … 8 AWG
Fine-stranded conductor0.5 … 10 mm² / 20 … 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 6 mm² / 20 … 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 … 6 mm² / 16 … 10 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length13 … 15 mm / 0.51 … 0.59 inches
Wiring directionFront-entry wiring

Physical data

Width7.5 mm / 0.295 inches
Height73.3 mm / 2.886 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches
Depth39.5 mm / 1.555 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colorblue
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.169 MJ
Weight12.7 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Commercial data

PU (SPU)25 pcs
Packaging typeBox
Country of originDE
GTIN4066966424126
Customs tariff number85369010000

Product Classification

UNSPSC39121410
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption