Fuse terminal block, 2002 Series, operating toolConnect conductors quickly and easily with this fuse terminal block (item number 2002-1612/1000-867). Conductors can only be connected to this fuse terminal block if their strip length is between 10 and 12 mm . This product features conductor terminals and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® connection technology is ideal for connecting all conductor types. Solid and fine-stranded conductors with ferrules can be pushed in without needing to use any tools—all thanks to its pluggable design. Depending on the type of conductor, this fuse terminal block is suitable for conductor cross sections ranging from 0.25 mm² to 4 mm².This product is designed for specific Ex applications (please refer to the product datasheet).

Specification

Notes

Safety InformationThe 2 mm test slot is only approved for high impedance measurement up to max. 100 mA.

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-3
Nominal voltage (III/3)250 V
Rated impulse withstand voltage (III / 3)6 kV
Rated current6.3 A
Blown fuse indication120 V
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60947-7-3 / IEC/EN 60947-7-3 / IEC/EN 60947-7-3
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage250 V
Rated impulse withstand voltage6 kV
Rated current6.3 A

Electrical data - Ratings per IEC/EN – Notes

Ratings (note)Electrical ratings are given by the fuse and blown fuse indication.
Rated current (note)Leakage current in case of a blown fuse: LED 2 mA

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)120 V
Rated current UL (Use Group B)10 A
Rated voltage UL (Use Group C)120 V
Rated current UL (Use Group C)10 A
Rated voltage UL (Use Group D)120 V
Rated current UL (Use Group D)10 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage120 V / 120 V / 120 V
Rated current10 A / 10 A / 10 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated current CSA (Use Group B)6.3 A
Rated voltage CSA (Use Group C)120 V
Rated current CSA (Use Group C)6.3 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage120 V
Rated current6.3 A

Electrical data - Ex information

Reference to hazardous areasSee “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Ratings perATEX: KIWA 17 ATEX 0030 U / IECEx: KIWA 17.0014U (Ex ec IIC Gc)
Rated voltage EN (Ex e II)120 V
Rated current (Ex e II)6.3 A

Electrical data - Power Loss

Power loss (max.) P<sub>l (max.)</sub> (note)When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
Maximum power loss P<sub>loss</sub> of fuse insert for overload and short-circuit protection (individual arrangement)1.6 W
Maximum power loss P<sub>loss</sub> of fuse insert for overload and short-circuit protection (block arrangement)1.6 W
Power loss P<sub>l</sub> max. short-circuit protection (individual arrangement)2.5 W
Power loss P<sub>loss</sub> (max.) of fuse cartridge for short-circuit protection (block arrangement)2.5 W

Electrical data - General information

Fuse receptaclepivoting
Fuse typeCylindrical fuse; 5 x 20 mm
Number/type of diode/LEDRed LED
Wiring directionFront-entry wiring

Connection data

Clamping units2
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section2.5 mm²
Solid conductor0.25 … 4 mm² / 22 … 12 AWG
Solid conductor; push-in termination0.75 … 4 mm² / 18 … 12 AWG
Fine-stranded conductor0.25 … 4 mm² / 22 … 12 AWG
Fine-stranded conductor; with insulated ferrule0.25 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination1 … 2.5 mm² / 18 … 14 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length10 … 12 mm / 0.39 … 0.47 inches
Wiring directionFront-entry wiring

Physical data

Width6.2 mm / 0.244 inches
Height66.1 mm / 2.602 inches
Depth from upper-edge of DIN-rail57.2 mm / 2.252 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colororange
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.288 MJ
Weight13.4 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Commercial data

PU (SPU)50 pcs
Packaging typeBox
Country of originCN
GTIN4066966312973
Customs tariff number85369095000

Product Classification

UNSPSC39121410
ETIM 9.0EC000899
ETIM 10.0EC000899
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1
REACH Candidate List SubstanceDiboron trioxide, Lead, Lead monoxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption7(c)-I
SCIP notification number (Austria)a178a51d-be93-42a8-88bf-11740f79dbce
SCIP notification number (Belgium)b6df4f49-82f4-4d9f-bc3a-b5289f5f18b6
SCIP notification number (Bulgaria)c45f9463-e332-4714-8908-3764a6b8e050
SCIP notification number (Czech Republic)749bf80f-5d91-473c-bbbc-b63e0da8007d
SCIP notification number (Denmark)96a0c113-fd83-457c-93bb-645a45ed05d4
SCIP notification number (Finland)429f70db-5f38-4ca9-8442-402418e1578f
SCIP notification number (France)012eed9a-9399-431a-8bd3-57131a4c9892
SCIP notification number (Germany)034fa358-945f-4982-9acc-e49072de6921
SCIP notification number (Hungary)c52a93c0-af9d-468a-8526-2344a9547b1b
SCIP notification number (Italy)ed1f89f5-274b-479a-baec-7d7338b8f5b4
SCIP notification number (Netherlands)5d05e323-6c25-46d8-af9f-830c5377d402
SCIP notification number (Poland)080bcd6e-1355-4c9a-9f04-fe3c10a28b3d
SCIP notification number (Romania)ad259ab2-fb54-4309-8f73-2dc67f85c1c6
SCIP notification number (Sweden)d9a525f6-db1f-48c3-ad49-00b845770f50