ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65, 1x SinCos EnDat 2.1/SSI/BiSS encoder interface, cold plate mounting
Specification
| Module type | ACOPOSremote module |
|---|---|
| B&R ID code | 0xDDA4 |
| Power contacts | Max. 20 A at 40°C |
| Dynamic node allocation (DNA) | Yes |
| Cooling and mounting type | Cold plate mounting |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| Functional safety | Yes |
| UL | cULus E225616 Power conversion equipment |
| Nominal | 5 to 40°C |
| Continuous power consumption | In preparation |
| Switching frequency 5 kHz | 10 m |
| Switching frequency 10 kHz | 5 m |
| Switching frequency 20 kHz | 5 m |
| DC bus capacitance | 35 µF |
| Variant | M8 connector |
| Maximum | 60°C |
| Input voltage | 24 VDC +20% / -25% |
| Input capacitance | In preparation |
| Max. power consumption | 10 W + P24 V out + PHolding brake + PTrigger |
| Quantity | 1 |
| Output voltage | 5 V ±5% |
| Continuous current | Max. 8 A (max. 4 A per pin) |
| Fuse protection | Electronic (per pin) |
| 24 VDC, COM | M8 connector |
| Continuous power per motor connection | 4 kW |
| Continuous current per motor connection | 8.8 Aeff |
| Starting at 500 m above sea level | 0.88 A per 1,000 m |
| Peak current | 24.5 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| U, V, W, PE | 8-pin speedtec connector, size 1 |
| Shield connection | Yes (via connector housing) |
| Continuous current per connection | 1.1 A |
| Max. internal resistance | In preparation |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. switching frequency | 0.5 Hz |
| Overload and short-circuit protection | Yes |
| Open-circuit monitoring | Yes |
| Undervoltage monitoring | Yes |
| Response threshold for open-circuit monitoring | Approx. 0.25 A |
| Response threshold for undervoltage monitoring | 24 VDC +0% / -4% |
| Type | EnDat 2.1 |
| Line length | Max. 100 m between two stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Module-side connection | 15-pin female springtec connector |
| Status indicators | UP/DN LEDs |
| Encoder - ACOPOSremote | No |
| Encoder monitoring | Yes |
| Max. encoder cable length | 10 m |
| Load capacity | 250 mA |
| Sense lines | 2, compensation of max. 2 x 0.7 V |
| Overload-proof | Yes |
| Short-circuit proof | Yes |
| Signal transmission | RS485 |
| Signal frequency (-3 dB) | DC up to 300 kHz |
| Signal frequency (-5 dB) | DC up to 400 kHz |
| Differential voltage | 0.5 to 1.25 Vss |
| Common-mode voltage | Max. ±7 V |
| Terminating resistor | 120 Ω |
| Resolution | 12-bit |
| Differential voltage for low | ≤-0.2 V |
| Differential voltage for high | ≥0.2 V |
| Resolution @ 1 VSS | Number of encoder lines * 5700 |
| Accuracy | – |
| Noise | – |
| Data transfer rate | Depends on the configured functionality |
| Circuit | Sink |
| Input - Inverter module | No |
| Input - Input | No |
| Input current at nominal voltage | In preparation |
| Low | <5 V |
| High | >15 V |
| Enable 1 → 0, PWM off | Max. 20.5 ms |
| Enable 0 → 1, ready for PWM | Max. 100 µs |
| Modulation compared to ground potential | In preparation |
| OSSD signal connections | Permitted Max. test pulse length: 500 µs |
| Rising edge | In preparation |
| Falling edge | In preparation |
| Max. line length | 30 m |
| Resistance range | 500 Ω to 5 kΩ |
| ACP10 | V2.35.1 and higher |
| Discharge capacitance | 0.1 µF |
| Power dissipation relative to continuous apparent power | IE2 (10,25) 1.8% IE2 (50,25) 1.8% IE2 (10,50) 2% IE2 (50,50) 2% IE2 (90,50) 2% IE2 (10,100) 2.4% IE2 (50,100) 2.4% IE2 (90,100) 2.4% |
| Nominal losses in standby mode | 6.5 W |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | Yes |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP65 |
| Storage | 5 to 95%, non-condensing |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85%, non-condensing |
| Width | 137 mm |
| Height | 287.2 mm |
| Depth | 131 mm |
| Weight | 4.8 kg |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0