Fast delivery within 72 Hours
B&R 8CVI088E1HCS0.00-1
ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65, 1x SinCos EnDat 2.1/SSI/BiSS encoder interface, cold plate mounting
Shipping & Delivery
- 
Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery
 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year
 
- 
Free 30-Day returns
 
Description
ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65, 1x SinCos EnDat 2.1/SSI/BiSS encoder interface, cold plate mounting
Specification
| Module type | 
 ACOPOSremote module  | 
|---|---|
| B&R ID code | 
 0xDDA4  | 
| Power contacts | 
 Max. 20 A at 40°C  | 
| Dynamic node allocation (DNA) | 
 Yes  | 
| Cooling and mounting type | 
 Cold plate mounting  | 
| CE | 
 Yes  | 
| UKCA | 
 Yes  | 
| CRA (Cyber Resilience Act) | 
 In preparation  | 
| Functional safety | 
 Yes  | 
| UL | 
 cULus E225616  | 
| Nominal | 
 5 to 40°C  | 
| Continuous power consumption | 
 In preparation  | 
| Switching frequency 5 kHz | 
 10 m  | 
| Switching frequency 10 kHz | 
 5 m  | 
| Switching frequency 20 kHz | 
 5 m  | 
| DC bus capacitance | 
 35 µF  | 
| Variant | 
 M8 connector  | 
| Maximum | 
 60°C  | 
| Input voltage | 
 24 VDC +20% / -25%  | 
| Input capacitance | 
 In preparation  | 
| Max. power consumption | 
 10 W + P24 V out + PHolding brake + PTrigger  | 
| Quantity | 
 1  | 
| Output voltage | 
 5 V ±5%  | 
| Continuous current | 
 Max. 8 A (max. 4 A per pin)  | 
| Fuse protection | 
 Electronic (per pin)  | 
| 24 VDC, COM | 
 M8 connector  | 
| Continuous power per motor connection | 
 4 kW  | 
| Continuous current per motor connection | 
 8.8 Aeff  | 
| Starting at 500 m above sea level | 
 0.88 A per 1,000 m  | 
| Peak current | 
 24.5 Aeff  | 
| Nominal switching frequency | 
 5 kHz  | 
| Possible switching frequencies | 
 5 / 10 / 20 kHz  | 
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | 
 Limit value curve A  | 
| Overload protection | 
 Yes  | 
| Short-circuit and ground fault protection | 
 Yes  | 
| Max. output frequency | 
 598 Hz  | 
| U, V, W, PE | 
 8-pin speedtec connector, size 1  | 
| Shield connection | 
 Yes (via connector housing)  | 
| Continuous current per connection | 
 1.1 A  | 
| Max. internal resistance | 
 In preparation  | 
| Extinction potential | 
 Approx. 30 V  | 
| Max. extinction energy per switching operation | 
 1.5 Ws  | 
| Max. switching frequency | 
 0.5 Hz  | 
| Overload and short-circuit protection | 
 Yes  | 
| Open-circuit monitoring | 
 Yes  | 
| Undervoltage monitoring | 
 Yes  | 
| Response threshold for open-circuit monitoring | 
 Approx. 0.25 A  | 
| Response threshold for undervoltage monitoring | 
 24 VDC +0% / -4%  | 
| Type | 
 EnDat 2.1  | 
| Line length | 
 Max. 100 m between two stations (segment length)  | 
| Transfer rate | 
 100 Mbit/s  | 
| Module-side connection | 
 15-pin female springtec connector  | 
| Status indicators | 
 UP/DN LEDs  | 
| Encoder - ACOPOSremote | 
 No  | 
| Encoder monitoring | 
 Yes  | 
| Max. encoder cable length | 
 10 m  | 
| Load capacity | 
 250 mA  | 
| Sense lines | 
 2, compensation of max. 2 x 0.7 V  | 
| Overload-proof | 
 Yes  | 
| Short-circuit proof | 
 Yes  | 
| Signal transmission | 
 RS485  | 
| Signal frequency (-3 dB) | 
 DC up to 300 kHz  | 
| Signal frequency (-5 dB) | 
 DC up to 400 kHz  | 
| Differential voltage | 
 0.5 to 1.25 Vss  | 
| Common-mode voltage | 
 Max. ±7 V  | 
| Terminating resistor | 
 120 Ω  | 
| Resolution | 
 12-bit  | 
| Differential voltage for low | 
 ≤-0.2 V  | 
| Differential voltage for high | 
 ≥0.2 V  | 
| Resolution @ 1 VSS | 
 Number of encoder lines * 5700  | 
| Accuracy | 
 –  | 
| Noise | 
 –  | 
| Data transfer rate | 
 Depends on the configured functionality  | 
| Circuit | 
 Sink  | 
| Input - Inverter module | 
 No  | 
| Input - Input | 
 No  | 
| Input current at nominal voltage | 
 In preparation  | 
| Low | 
 <5 V  | 
| High | 
 >15 V  | 
| Enable 1 → 0, PWM off | 
 Max. 20.5 ms  | 
| Enable 0 → 1, ready for PWM | 
 Max. 100 µs  | 
| Modulation compared to ground potential | 
 In preparation  | 
| OSSD signal connections | 
 Permitted  | 
| Rising edge | 
 In preparation  | 
| Falling edge | 
 In preparation  | 
| Max. line length | 
 30 m  | 
| Resistance range | 
 500 Ω to 5 kΩ  | 
| ACP10 | 
 V2.35.1 and higher  | 
| Discharge capacitance | 
 0.1 µF  | 
| Power dissipation relative to continuous apparent power | 
 IE2 (10,25) 1.8%  | 
| Nominal losses in standby mode | 
 6.5 W  | 
| Hanging vertically | 
 Yes  | 
| Horizontal, face up | 
 Yes  | 
| Standing horizontally | 
 Yes  | 
| Pollution degree per EN 61800-5-1 | 
 2 (non-conductive pollution)  | 
| Overvoltage category per EN 61800-5-1 | 
 III  | 
| Degree of protection per EN 60529 | 
 IP65  | 
| Storage | 
 5 to 95%, non-condensing  | 
| Transport | 
 Max. 95% at 40°C  | 
| Operation | 
 5 to 85%, non-condensing  | 
| Width | 
 137 mm  | 
| Height | 
 287.2 mm  | 
| Depth | 
 131 mm  | 
| Weight | 
 4.8 kg  | 
	
	
				
		
		
		
		
		
		
		