Fast delivery within 72 Hours
B&R 8BVP1650HC00.000-1
Wide input voltage rangeCapable of regenerationIntegrated connection for temperature sensors2 slots for ACOPOSmulti plug-in modules
ACOPO…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Wide input voltage rangeCapable of regenerationIntegrated connection for temperature sensors2 slots for ACOPOSmulti plug-in modules
ACOPOSmulti power supply module, 165 A, AS, cold plate or pass-through mounting
Specification
| B&R ID code |
0xAD85 |
|---|---|
| Dynamic node allocation (DNA) |
Yes |
| Cooling and mounting type |
Cold plate or pass-through mounting |
| Slots for plug-in modules |
2 |
| CE |
Yes |
| UKCA |
Yes |
| UL |
cULus E225616 |
| KC |
Yes |
| Network configurations |
TT, TN-S, TN-C-S |
| Mains input voltage |
3x 220 to 3x 480 VAC ±10% |
| Frequency |
50 / 60 Hz ±4% |
| Total harmonic distortion current (THDi) |
<0.2% |
| Total harmonic distortion voltage (THDu) |
<1% |
| Installed load |
Max. 124 kW |
| Inrush current at 400 VAC |
Max. 102 A |
| Switch-on interval |
>800 s |
| 230 VAC |
69.7 mF |
| 400 VAC |
23 mF |
| 480 VAC |
16 mF |
| Nominal switching frequency |
5 kHz |
| Possible switching frequencies |
5 / 10 kHz |
| Integrated line filter per EN 61800-3, category C3 |
No |
| Integrated regeneration choke |
No |
| Regenerative |
Yes |
| Power factor correction (PFC) |
Yes |
| Line fuse |
Max. 495 A (gG fuses per IEC 60269-1 or Class CC, J, T) |
| L1, L2, L3, PE |
M8 threaded bolts |
| Shield connection |
Yes |
| Flexible and fine-stranded wires |
— |
| Terminal cable cross section dimension of shield connection |
32 to 50 mm |
| Nominal |
5 to 40°C |
| Continuous power (supply and regeneration) |
120 kW |
| Mains input voltage <3x 400 VAC |
300 W/V * (400 V – Mains input voltage) |
| UDC <750 VDC |
P * (1 – UDC/750) |
| Cold plate mounting |
1.3 kW/K (starting at 17°C) |
| Pass-through mounting |
209 mm |
| Starting at 500 m above sea level |
12 kW per 1000 m |
| Peak power (supply and regeneration) |
240 kW |
| Switching frequency 5 kHz |
[0.043 * P² + 8.09 * P + 1452] W |
| Switching frequency 10 kHz |
[0.053 * P² + 8.76 * P + 2084] W |
| DC bus capacitance |
3630 µF |
| Overload protection |
No |
| Short-circuit and ground fault protection |
No |
| Variant |
ACOPOSmulti backplane |
| Input voltage |
25 VDC ±1.6% |
| Input capacitance |
4.7 µF |
| Max. power consumption |
37 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF… |
| Quantity |
2 |
| DC bus voltage (UDC): 260 to 315 VDC |
25 VDC * (UDC / 315) |
| DC bus voltage (UDC): 315 to 800 VDC |
24 VDC ±6% |
| Fuse protection |
250 mA (slow-blow) electronic, automatic reset |
| Output voltage |
24 V +5.8% / -0.1% |
| Continuous current |
4.2 A |
| Max. overcurrent limiting |
10 A |
| Short-circuit proof |
Yes |
| Open-circuit monitoring |
No |
| Undervoltage monitoring |
No |
| Circuit |
Sink |
| Input - Power supply module |
Yes |
| Input - Input |
Yes |
| Maximum |
55°C |
| Low |
<5 V |
| High |
>15 V |
| Input current at nominal voltage |
Approx. 10 mA |
| Rising edge |
52 μs ±0.5 μs (digitally filtered) |
| Falling edge |
53 μs ±0.5 μs (digitally filtered) |
| Modulation compared to ground potential |
Max. ±38 V |
| Discharge capacitance |
1.8 µF |
| Power dissipation relative to continuous apparent power |
IE2 (10,25) 0.2% |
| Nominal losses in standby mode |
13.5 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
III |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
427.5 mm |
| Height |
317 mm |
| Cold plate |
212 mm |
| Weight |
Approx. 18.4 kg |