Fast delivery within 72 Hours

B&R 8BVP0440HW00.000-1

Wide input voltage rangeCapable of regenerationIntegrated connection for temperature sensors2 slots for ACOPOSmulti plug-in modules

ACOPO…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Wide input voltage rangeCapable of regenerationIntegrated connection for temperature sensors2 slots for ACOPOSmulti plug-in modules

ACOPOSmulti power supply module, 44 A, AS, wall mounting

Specification

B&R ID code0xA074
Dynamic node allocation (DNA)Yes
Cooling and mounting typeWall mounting
Slots for plug-in modules2
CEYes
UKCAYes
CRA (Cyber Resilience Act)Evaluation ongoing
ULcULus E225616 Power conversion equipment
KCYes
Network configurationsTT, TN-S, TN-C-S
Mains input voltage3x 220 to 3x 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 31.1 kW
Inrush current at 400 VACMax. 67 A
Switch-on interval>300 s
230 VAC17.4 mF
400 VAC5.8 mF
480 VAC4 mF
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 kHz
Integrated line filter per EN 61800-3, category C3No
Integrated regeneration chokeNo
RegenerativeYes
Power factor correction (PFC)Yes
Line fuseMax. 132 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 110 A (circuit breaker per EN 60947-2 or UL 489)
L1, L2, L3, PEConnector
PEM5 threaded bolt
Shield connectionYes
With wire end sleeve0.5 to 16 mm²
UL/C-UL-US20 to 6 AWG
CSA20 to 6 AWG
Terminal cable cross section dimension of shield connection23 to 35 mm
Nominal5 to 40°C
Continuous power (supply and regeneration)30 kW
Mains input voltage <3x 400 VAC150 W/V * (400 V – Mains input voltage)
UDC <750 VDCP * (1 – UDC/750)
Switching frequency 5 kHz[0.15*P²+10.5*P+40] W
Switching frequency 10 kHz[0.42*P²+16*P+130] W
Starting at 500 m above sea level3 kW per 1000 m
Peak power (supply and regeneration)60 kW
DC bus capacitance825 µF
Overload protectionNo
Short-circuit and ground fault protectionNo
VariantACOPOSmulti backplane
Input voltage25 VDC ±1.6%
Input capacitance4.7 µF
Max. power consumption25 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF…
Quantity2
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC / 315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
Output voltage24 V +5.8% / -0.1%
Continuous current4.2 A
Max. overcurrent limiting10 A
Short-circuit proofYes
Open-circuit monitoringNo
Undervoltage monitoringNo
CircuitSink
Input - Power supply moduleYes
Input - InputYes
Maximum55°C
Low<5 V
High>15 V
Input current at nominal voltageApprox. 10 mA
Rising edge52 μs ±0.5 μs (digitally filtered)
Falling edge53 μs ±0.5 μs (digitally filtered)
Modulation compared to ground potentialMax. ±38 V
Discharge capacitance0.9 µF
Power dissipation relative to continuous apparent powerIE2 (10,25) 0.6% IE2 (50,25) 0.6% IE2 (10,50) 0.6% IE2 (50,50) 0.8% IE2 (90,50) 1.3% IE2 (10,100) 0.6% IE2 (50,100) 1.3% IE2 (90,100) 2.4%
Nominal losses in standby mode10.8 W
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width106.5 mm
Height317 mm
Wall mounting263 mm
WeightApprox. 5.5 kg
Module width2

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8BVP0440HW00.000-1”