Fast delivery within 72 Hours

B&R 8BVI0880HWS0.004-1

Integrated uncontrolled and safe stopsIntegrated connection for motor holding brake and temperature sensor2 slots for ACOPOSmulti plug-in modules…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Integrated uncontrolled and safe stopsIntegrated connection for motor holding brake and temperature sensor2 slots for ACOPOSmulti plug-in modules

ACOPOSmulti inverter module, 88 A, AS, wall mounting

Specification

B&R ID code0xA69F
Dynamic node allocation (DNA)Yes
Cooling and mounting typeWall mounting
Slots for plug-in modules2
CEYes
UKCAYes
Functional safetyYes
ULcULus E225616 Power conversion equipment
KCYes
Nominal5 to 40°C
Continuous power consumption65 kW
Switching frequency 5 kHz25 m
Switching frequency 10 kHz25 m
Switching frequency 20 kHz25 m
DC bus capacitance1980 µF
VariantACOPOSmulti backplane
Input voltage25 VDC ±1.6%
Input capacitance32.9 µF
Max. power consumption27 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake
Quantity1
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
Continuous power per motor connection64 kW
Continuous current per motor connection88 Aeff
Starting at 500 m above sea level8.8 Aeff per 1000 m
Peak current176 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Overload protectionYes
Short-circuit and ground fault protectionYes
Max. output frequency598 Hz
U, V, W, PEM8 threaded bolts
Shield connectionYes
Flexible and fine-stranded wires
Terminal cable cross section dimension of shield connection12 to 50 mm
Output voltage24 VDC +5.8% / -0%
Continuous current per connection4.2 A
Max. internal resistance0.15 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation3 Ws
Max. switching frequency0.5 Hz
Overload and short-circuit protectionYes
Open-circuit monitoringYes
Undervoltage monitoringYes
Response threshold for open-circuit monitoringApprox. 0.5 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%
CircuitSink
Input - Inverter moduleYes
Input - InputYes
Maximum55°C
Input current at nominal voltageApprox. 10 mA
Low<5 V
High>15 V
Enable 1 → 0, PWM offMax. 20.5 ms
Enable 0 → 1, ready for PWMMax. 100 µs
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted Max. test pulse length: 500 µs
Rising edge52 µs ±0.5 µs (digitally filtered)
Falling edge53 µs ±0.5 µs (digitally filtered)
Resistance range500 Ω to 5 kΩ
Discharge capacitance0.44 µF
Power dissipation relative to continuous apparent powerIE2 (10,25) 0.7% IE2 (50,25) 0.7% IE2 (10,50) 1% IE2 (50,50) 1% IE2 (90,50) 1% IE2 (10,100) 1.6% IE2 (50,100) 1.6% IE2 (90,100) 1.6%
Nominal losses in standby mode10.5 W
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width213.5 mm
Height317 mm
Wall mounting263 mm
WeightApprox. 10.9 kg
Module width4