Fast delivery within 72 Hours

B&R 8B0P0220HW00.000-1

Wide input voltage rangeIntegrated connection for external braking resistor

ACOPOSmulti power supply module passive, 22 A, AS, wall mount…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Wide input voltage rangeIntegrated connection for external braking resistor

ACOPOSmulti power supply module passive, 22 A, AS, wall mounting

Specification

B&R ID code0xA8E9
Dynamic node allocation (DNA)Yes
Cooling and mounting typeWall mounting
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ULcULus E225616 Power conversion equipment
KCYes
Network configurationsTT, TN-S, TN-C-S
Mains input voltage3x 380 to 3x 500 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 15.6 kVA
Power dissipation with continuous powerIn preparation
Inrush current at 400 VAC10 A
Switch-on interval>120 s
400 VAC14.4 mF
480 VAC10 mF
Integrated line filter per EN 61800-3, category C3No
Integrated regeneration chokeNo
RegenerativeNo
Power factor correction (PFC)No
Line fuseMax. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 55 A (circuit breaker per EN 60947-2 or UL 489)
L1, L2, L3, PEConnector
PEM5 threaded bolt
Shield connectionYes
With wire end sleeve0.5 to 6 mm²
UL/C-UL-US20 to 8 AWG
CSA20 to 8 AWG
Terminal cable cross section dimension of shield connection23 to 35 mm
Nominal5 to 40°C
Continuous power3 kW
Mains input voltage <3x 400 VAC20 W/V * (400 V – Mains input voltage)
Starting at 500 m above sea level0.8 kW per 1000 m
Reduction of continuous power depending on cooling methodIn preparation
Peak power output (supply)24 kW
DC bus capacitance660 µF
Overload protectionYes
Short-circuit and ground fault protectionYes (with RB+ by externally replaceable melting fuse)
VariantACOPOSmulti backplane
Input voltage25 VDC ±1.6%
Input capacitance23.5 µF
Max. power consumption12 W
Peak power output40 kW (max. 0.2 s)
Min. braking resistance12 Ω
Rated current of built-in fuse30 A (fast-acting)
RB+, RB-, PEConnector
Discharge capacitance0.9 µF
Power dissipation relative to continuous apparent powerIE2 (10;25) 0.4% IE2 (50;25) 0.5% IE2 (10;50) 0.4% IE2 (50;50) 0.6% IE2 (90;50) 0.8% IE2 (10;100) 0.5% IE2 (50;100) 0.8% IE2 (90;100) 1.5%
Nominal losses in standby mode6 W
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Maximum55°C
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width106.5 mm
Height317 mm
Wall mounting263 mm
WeightApprox. 5.9 kg
Module width2