Fast delivery within 72 Hours

B&R 8B0C0320HC00.B00-1

ACOPOSmulti auxiliary supply module, 35 A, AS, cold plate or pass-through mounting, 42…58 VOut

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSmulti auxiliary supply module, 35 A, AS, cold plate or pass-through mounting, 42…58 VOut

Specification

Cooling and mounting typeCold plate
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ULcULus E225616 Power conversion equipment
Nominal5 to 40°C
Operating range in continuous operation260 to 800 VDC
Full continuous power550 to 800 VDC
Continuous power consumptionMax. 2120 W
Power dissipation with continuous power15 W (0% continuous power) 30 W (50% continuous power) 90 W (100% continuous power)
DC bus capacitance1.2 µF
VariantConnector
Quantity1
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
24 VDC, COMConnector
Input voltage25 VDC ±1.6%
Input capacitance47 µF
Max. power consumption7 W + P 24 VDC Out
Workspace42 to 58 VDC
Residual rippleTyp. 200 mVSS
Input stabilityTyp. <50 mV (dynamic)
Load stability250 mVSS (dynamic)
Continuous power(Output voltage / 58 VDC) * 2030 W
Continuous current±35 A
Peak current±60 A (max. 2 s)
Depending on ambient temperature0.2 A/K (starting at 40°C)
Depending on installation elevation3.5 A per 1000 m (starting at 500 m above sea level)
Depending on the input voltage0,136 A/V * (600 V – Input voltage)
Depending on cooling typeNo reduction
Startup delayMax. 8 s
Startup timeTyp. 300 ms
No-load proofYes
Overload-proofYes
Short-circuit proofYes
Feedback protectionYes <63 V
Overtemperature protectionYes
Output/Input isolationPELV
Shield connectionYes
ConnectionParallel connection on output: Not permitted Serial connection on output: Not permitted
Max. cable length30 m
TypePOWERLINK V2 controlled node (CN)
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Modulation compared to ground potential±38 VDC
CircuitSink
Input current at nominal voltageTyp. 10 mA
Switching thresholdLOW: 15 VDC
Maximum55°C
Electrical isolationYes
Rising edge52 ±0.5 µs (digitally filtered)
Falling edge53 ±0.5 µs (digitally filtered)
ShieldingNo
VoltageMax. 30 VDC
CurrentMax. 100 mA
Loop through for STOYes
Load pulse3 mA
Pulse durationMax. 500 ms
Threshold value for undervoltage warning5.2 V
Idle currentMax. 10 µA
Mapp Motion5.13.1 and higher
ACP10/ARNC0All versions
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width53.5 mm
Height317 mm
Cold plate212 mm
Weight2.6 kg
Module width1

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8B0C0320HC00.B00-1”