Fast delivery within 72 Hours

Festo VSVA-B-M52-MZD-A1-1T1L-ANP

For valve terminal VTSA/VTSA-F , Robust metal housing

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

For valve terminal VTSA/VTSA-F , Robust metal housing

Specification

Valve Function5/2-way, monostable
Type Of ActuationElectric
Construction Width26 mm
Standard Nominal Flow Rate (Standardised To Din 1343)1100 l/min
Pneumatic Working PortSub-base size 26 mm to ISO 15407-2, G1/4
Operating Voltage24V DC
Operating Pressure-0.9, 10 bar
DesignPiston gate valve
Type Of ResetMechanical spring
Kc MarkKC-EMV
Ce Mark (See Declaration Of Conformity)To EU EMC Directive
Ukca Marking (See Declaration Of Conformity)To UK instructions for EMC
Degree Of ProtectionIP65, NEMA 4
Nominal Size9 mm
Exhaust Air FunctionWith flow control option, Via throttle plate, Via individual sub-base
Sealing PrincipleSoft
Mounting Positionoptional
Manual OverrideDetenting, Non-detenting, Covered
Type Of PilotingPilot actuated
Pilot Air SupplyExternal, Internal
Flow Directionoptional
Symbol00997391
Measuring PrincipleInductive
LapOverlap
Reverse Polarity Protection SensorFor all electrical connections
Signal Status DisplayLED
Switching Position SensingNormal position via sensor
Switching Status Display SensorLED
Pilot Pressure3, 10 bar
Flow Rate Of Valve1400 l/min
Flow Rate Of Valve On Individual Sub Base1200 l/min
Valve Flow Rate, Pneumatically Linked, Flow Optimized1350 l/min
Flow Rate Of Pneumatically Interlinked Valve1100 l/min
Switching Time Off54 ms
Switching Time On20 ms
Valve Sensor Switching Time On60 ms
Valve Sensor Switching Time Off11 ms
Duty Cycle100%
Max. Positive Test Pulse With Signal1200 µs
Max. Negative Test Pulse With 1 Signal1100 µs
Nominal Operating Voltage Dc24 V
Switching OutputNPN
Characteristic Coil Data24 V DC: 1.6 W
Immunity To Surge2.5 kV
Pollution Degree3
Permissible Voltage Fluctuations+/- 10 %
Operating MediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note On Operating And Pilot MediumLubricated operation possible (in which case lubricated operation will always be required)
Vibration ResistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock ResistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion Resistance Class Crc0 – No corrosion stress
Labs (Pwis) ConformityVDMA24364-B1/B2-L
Media Temperature-5, 50 °C
Relative Air Humidity0 – 90%
Sound Pressure Level85 dB(A)
Ambient Temperature-5, 50 °C
Max. Tightening Torque For Valve Mounting1.8, 2.2 Nm
Product Weight264 g
Operating Voltage Range, Dc Sensor10, 30 V
Short Circuit Strength SensorPulsed
Idle Current Sensor10 mA
Max. Output Current Sensor200 mA
Max. Switching Frequency Sensor5000 Hz
Residual Ripple Sensor± 10%
Voltage Drop Sensor2 V
Electrical Connection4-pin, Plugs, To ISO 15407-2
Sensor ConnectionPlug, 3-pin, M8x1
Type Of MountingOn sub-base
Pilot Air Port 12/14Sub-base size 26 mm to ISO 15407-2
Pilot Exhaust Port 82/84Ducted, Not ducted, Either:
Pneumatic Connection, Port 1Sub-base size 26 mm to ISO 15407-2
Pneumatic Connection, Port 2Sub-base size 26 mm to ISO 15407-2
Pneumatic Connection, Port 3Sub-base size 26 mm to ISO 15407-2
Pneumatic Connection, Port 4Sub-base size 26 mm to ISO 15407-2
Pneumatic Connection, Port 5Sub-base size 26 mm to ISO 15407-2
Note On MaterialsRoHS-compliant
Material SealsFPM, NBR
Material HousingDie-cast aluminium, PA
Material ScrewsGalvanised steel
Switching Element FunctionN/C contact

Customer Reviews