100 to 240 VAC wide-range inputHigh dielectric strengthCan be connected in parallel for increased capacity and redundancyReliable operation due to long power failure bypass function under full load and high MTBF (>500,000 h)International certification packageWide temperature range from -25 to 70°CClosed metal housing

24 VDC power supply, 1-phase, 20 A, input 100 to 240 VAC, wide range, top-hat rail installation

Specification

Status displayGreen LED (DC OK), threshold value Uout = 21.5 V
Input - Output4 kV AC (type test) 2 kV AC (routine test)
Input - Ground2 kV AC (type test) 2 kV AC (routine test)
Output - Ground500 VDC (type test)
Connection typeScrew terminal
Wire end sleevesFlexible cables require wire end sleeves in order to fulfill EN 62368 / UL 60950
Flexible0.5 to 4 mm² / 20 to 10 AWG
Inflexible0.5 to 6 mm² / 20 to 10 AWG
Wire stripping length9 mm (input) 14 mm (output)
CEYes
UKCAYes
CRA (Cyber Resilience Act)Evaluation ongoing
ULcULus E123528 Industrial control equipment
Nominal input voltage100 to 240 VAC
Input voltageAC 85 to 264 V (wide range), 45 to 65 Hz
Input currentApprox. 4.6 A (120 VAC) Approx. 2.4 A (230 VAC)
Inrush current limiting<15 A
I2t1.4 A2s
Power failure bypass>13 ms (120 VAC) >13 ms (230 VAC)
Switch-on time<1 s (typical)
Power factor (cos φ)0.99
Leakage current to PE<3.5 mA
Protective circuitTransient surge protection with varistor
Internal fuse10 A slow-blow
Required line fuse for line protection16 A (characteristic B)
Input voltage <90 VACDerating from output current: 2.5% per °C
Nominal voltage24 VDC ±1%
Output power480 W
Setting range for output voltage22.5 to 29.5 VDC
-25 to 55°C20.0 A
>55°CDerating: 2.5% per °C
Current limitingApprox. 25 A (for short circuit)
Control deviation<1% (static load change 10 to 90%) <2% (dynamic load change 10 to 90%) <0.1% (input voltage change ±10%)
Rise time<2 ms (UOUT (10 to 90%))
Residual ripple<10 mVSS
Switching peaks<80 mVSS
Can be connected in parallelYes, to establish redundancy and increase capacity
Can be connected in seriesYes
Max. capacitive loadUnlimited
Protection against internal overvoltagesYes, limited to <35 VDC
Protective functionsOutput protected against continuous short circuit, open circuit and overload
Power back immunityMax. 35 VDC
Output noise suppressionDevice complies with EN 55011 (class B)
Efficiency>91%
MTBF>500,000 h, per IEC 61709 (SN 29500)
Rated loadMax. 46 W
No-load operationMax. 4 W
HorizontalYes
VerticalNo
Maximum4000 m
Ventilation/CoolingNormal convection, no fan required
Degree of protection per EN 60529IP20
Protection classI, with PE connection
Operation30 g in each direction, per IEC 60068-2-27
Storage-40 to 85°C
Transport-40 to 85°C
Pollution degree2, per EN 50178
Climate category3K3, per EN 60721
MaterialSteel sheet, galvanized Side panels: Aluminum
InstallationEasy top-hat rail installation (NS 35 rails, EN 60715)
Width115 mm
Height130 mm
Depth152.5 mm