100 to 240 VAC wide-range inputHigh dielectric strengthCan be connected in parallel for increased capacity and redundancyReliable operation due to long power failure bypass function under full load and high MTBF (>500,000 h)International certification packageWide temperature range from -25 to 70°CClosed metal housing

24 VDC power supply, 1-phase, 10 A, input 100 to 240 VAC, wide range, top-hat rail installation

Specification

Status display

Green LED (DC OK), threshold value Uout = 21.5 V

Input - Output

4 kV AC (type test)
2 kV AC (routine test)

Input - Ground

2 kV AC (type test)
2 kV AC (routine test)

Output - Ground

500 VDC (type test)

Connection type

Screw terminal

Wire end sleeves

Flexible cables require wire end sleeves in order to fulfill EN 62368 / UL 60950

Flexible

0.2 to 2.5 mm² / 24 to 14 AWG

Inflexible

0.2 to 2.5 mm² / 24 to 14 AWG

Wire stripping length

9 mm (input/output)

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

Evaluation ongoing

UL

cULus E123528
Industrial control equipment

Nominal input voltage

100 to 240 VAC

Input voltage

AC 85 to 264 V (wide range), 45 to 65 Hz
300 VAC (temporary)

Input current

Approx. 3 A (100 VAC)
Approx. 1.5 A (240 VAC)

Inrush current limiting

<15 A

I2t

0.7 A2s

Power failure bypass

>24 ms (120 VAC)
>24 ms (230 VAC)

Switch-on time

<1 s (typical)

Power factor (cos φ)

0.99

Leakage current to PE

<3.5 mA

Protective circuit

Transient surge protection with varistor

Internal fuse

6.3 A slow-blow

Required line fuse for line protection

10 A
16 A (characteristic B)

Input voltage <90 VAC

Derating from output current: 2.5% per °C

Nominal voltage

24 VDC ±1%

Output power

240 W

Setting range for output voltage

22.5 to 29.5 VDC

-25 to 55°C

10.0 A

>55°C

Derating: 2.5% per °C

Current limiting

Approx. 14 A (for short circuit)

Control deviation

<1% (static load change 10 to 90%)
<2% (dynamic load change 10 to 90%)
<0.1% (input voltage change ±10%)

Rise time

<2 ms (UOUT (10 to 90%))

Residual ripple

<10 mVSS

Switching peaks

<50 mVSS

Can be connected in parallel

Yes, to establish redundancy and increase capacity

Can be connected in series

Yes

Max. capacitive load

Unlimited

Protection against internal overvoltages

Yes, limited to <35 VDC

Protective functions

Output protected against continuous short circuit, open circuit and overload

Power back immunity

Max. 35 VDC

Output noise suppression

Device complies with EN 55011 (class B)

Efficiency

>89%

MTBF

>500,000 h, per IEC 61709 (SN 29500)

Rated load

Max. 30 W

No-load operation

Max. 6.7 W

Horizontal

Yes

Vertical

No

Maximum

5000 m

Ventilation/Cooling

Normal convection, no fan required

Degree of protection per EN 60529

IP20

Protection class

I, with PE connection

Operation

30 g in each direction, per IEC 60068-2-27

Storage

-40 to 85°C

Transport

-40 to 85°C

Pollution degree

2, per EN 50178

Climate category

3K3, per EN 60721

Material

Steel sheet, galvanized
Side panels: Aluminum

Installation

Easy top-hat rail installation (NS 35 rails, EN 60715)

Width

60 mm

Height

130 mm

Depth

152.5 mm

Weight

1400 g