Fast delivery within 72 Hours

B&R 0PS1040.0

100 to 240 VAC wide-range inputPower boost for reliable startup of demanding loads (up to 5 A)Can be connected in parallel for increased capacity and redundancyActive DC OK switch outputReliable opera…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

100 to 240 VAC wide-range inputPower boost for reliable startup of demanding loads (up to 5 A)Can be connected in parallel for increased capacity and redundancyActive DC OK switch outputReliable operation due to long power failure bypass function under full load and high MTBF (>500,000 h)International certification packageWide temperature range from -25 to 70°CExtra slender design

24 VDC power supply, 1-phase, 4 A, input 100 to 240 VAC, wide range, top-hat rail installation

Specification

Status displayGreen LED (DC OK), threshold value Uout = 21.5 V
Input - Output3 kV AC (type test) 3 kV AC (routine test)
Active DC OK switch output24 V, 20 mA
Connection typeScrew terminal
Wire end sleevesFlexible cables require wire end sleeves in order to fulfill EN 62368 / UL 60950
Flexible0.2 to 2.5 mm² / 24 to 12 AWG
Inflexible0.2 to 2.5 mm² / 24 to 12 AWG
Wire stripping length7 mm (input/output)
CEYes
UKCAYes
CRA (Cyber Resilience Act)Evaluation ongoing
ULcULus E123528 Industrial control equipment
Nominal input voltage100 to 240 VAC
Input voltageAC 85 to 264 V (wide range), 45 to 65 Hz DC 90 to 350 V
Input currentApprox. 1.3 A (120 VAC) Approx. 0.8 A (230 VAC)
Inrush current limiting<20 A (typical)
I2t<2.1 A2s
Power failure bypass>20 ms (120 VAC) >100 ms (230 VAC)
Switch-on time<0.4 s
Protective circuitTransient surge protection with varistor
Internal fuse3.15 A slow-blow
Required line fuse for line protection6 A 10 A 16 A (characteristic B)
Nominal voltage24 VDC ±1%
Output power96 W
Setting range for output voltage22.5 to 28.5 VDC
-25 to 40°C5.0 A
40 to 60°C4.0 A
>60°CDerating: 2.5% per °C
Current limitingApprox. 9 A (for short circuit)
Control deviation<1% (static load change 10 to 90%) <3% (dynamic load change 10 to 90%) <0.1% (input voltage change ±10%)
Rise time0.3 ms (UOUT (10 to 90%))
Residual ripple<100 mVpp (at nominal values)
Switching peaks<100 mVSS (at nominal values)
Can be connected in parallelYes, to establish redundancy and increase capacity
Can be connected in seriesYes
Max. capacitive loadUnlimited
Protection against internal overvoltagesYes, limited to approximately 35 VDC
Protective functionsOutput protected against continuous short circuit, open circuit and overload
Power back immunityMax. 35 VDC
Output noise suppressionDevice complies with EN 55011 (class B)
Efficiency>88% (at 230 VAC and nominal values)
MTBF>500,000 h, per IEC 61709 (SN 29500)
Rated loadMax. 12 W
No-load operationMax. 2.5 W
HorizontalYes
VerticalNo
Maximum3000 m
Ventilation/CoolingNormal convection, no fan required
Degree of protection per EN 60529IP20
Protection classΙΙ (in closed control cabinet)
Operation30 g in all directions, per IEC 68-2-27
Storage-40 to 85°C
Transport-40 to 85°C
Pollution degree2, per EN 50178
Climate category3K3, per EN 60721
MaterialPolyamide PA, color green
InstallationEasy top-hat rail installation (NS 35 rails, EN 60715)
Width67.5 mm
Height99 mm
Depth114.5 mm
Weight400 g

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 0PS1040.0”