X20 SafeLOGIC-X controller (Safety+) 8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 4 safe type A digital outputs, 24 VDC, 3 A, OSSD

Specification

I/O module8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 4 safe type A digital outputs, 24 VDC, 3 A, OSSD <500 µs, 2 safe type B2 digital outputs, 24 VDC, 50 mA, OSSD <500 µs, SafeLOGIC-X technology
B&R ID code0x2F20
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software
InputsYes, using LED status indicator and software
ScopeModule
FunctionProgrammable
Standalone modeYes
Max. I/O cycle time800 µs
Bus0.4 W
Internal I/O2.5 W
Safe digital HS-LS outputs0.84
Safe digital HS-HS outputs0.175
Pulse outputs0.8
Channel - BusYes
Channel - ChannelNo
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
Functional safetyEN 50156-1:2004
ATEXIn preparation
ULIn preparation
NoteOrder 2x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
Quantity4
VariantPush-Pull
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Hardware≤150 µs
SoftwareConfigurable between 0 and 500 ms
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCMin. 2 mA to max. 3.28 mA
Input resistanceMin. 7.33 kΩ
Error detection time1 s
Insulation voltage between channel and bus500 Veff
Low<5 VDC
High>15 VDC
Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line Max. 400 m with shielded line
Nominal output current50 mA
Total nominal current200 mA
Output protectionShutdown of individual channels in the event of overload or short circuit
Braking voltage when switching off inductive loadsMax. 45 VDC
Error detection1 s
Peak short-circuit current0.5 A for 120 µs
Leakage current when the output is switched off0.1 mA
RDS(on)80 Ω
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Max. switching frequencySee section “Inrush current behavior for output channels”.
Test pulse lengthMax. 500 µs
Max. capacitive load100 nF
IOUT<100 µA
IGND<50 mA
Short-circuit current15 mAeff
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Horizontal mounting orientation0 to 60°C
Vertical mounting orientation0 to 50°C
DeratingSee section “Derating”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
Pitch25+0.2 mm