Fast delivery within 72 Hours

IFM SV5151

SV5151

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Reliable detection of flow and medium temperature
Precise linearized analogue output
Suitable for ultrapure water, water and water-based media
Durable and robust thanks to hydrolysis-resistant plastic
High precision of flow and temperature monitoring

Specification

Product characteristics

Number of inputs and outputsNumber of analogue outputs: 1
Measuring range1.8...32 l/min
0.265...4.716 m/s
1.8...32 l/min0.265...4.716 m/s
Process connectionthreaded connection G 3/4 external thread DN10

Application

Special featureGold-plated contacts
Measuring element1 x Pt 1000; (to DIN EN 60751, class B)
Applicationfor industrial applications
Installationconnection to pipe by means of an adapter
Mediaultra-pure water; water; glycol solutions; coolants
Medium temperature[°C] [°C]-15...125
Min. burst pressure25 bar
2.5 MPa
25 bar2.5 MPa
Note on min. burst pressure125 °C
Pressure rating16 bar
1.6 MPa
16 bar1.6 MPa
Note on pressure rating≤ 90 °C

Electrical data

Operating voltage[V] [V]8...33 DC
Current consumption[mA] [mA]< 5
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Power-on delay time[s] [s]< 2
Measuring principleVortex

Inputs / outputs

Number of inputs and outputsNumber of analogue outputs: 1

Outputs

Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]< (Ub - 8 V) / 20 mA; Ub = 24 V: 800

Measuring/setting range

Measuring range1.8...32 l/min
0.265...4.716 m/s
1.8...32 l/min0.265...4.716 m/s
Internal heating temperature probe1 K/mW
Measuring range[°C] [°C]-15...125

Accuracy / deviations

Accuracy (in the measuring range)water
Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW
glycol solutions (35%)
2 > v < 6 cSt: ± 5% MEW / 6 > v < 15 cSt: ± 10% MEW
waterQ < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW
glycol solutions (35%)2 > v < 6 cSt: ± 5% MEW / 6 > v < 15 cSt: ± 10% MEW
Repeatability0,2; (% of the final value)
Accuracy[K] [K]± 0,3 ± 0,005 x T

Response times

Response time[s] [s]0.34; (T09)
Dynamic response T05 / T09[s] [s]< 10 / < 30

Operating conditions

Ambient temperature[°C] [°C]-15...85
Note on ambient temperatureMedium temperature > 0 °C: -40...85
Storage temperature[°C] [°C]-40...85
ProtectionIP 65
CavitationP(absolute) discharge / P(difference) > 5.5 to avoid cavitation

Tests / approvals

EMCEN IEC 61326-1:2021
Shock resistanceDIN EN 60068-2-27
30 g (11 ms)
DIN EN 60068-2-2730 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
with water / 10...61 Hz 1 mm
with water / 61...2000 Hz 2 g
DIN EN 60068-2-6with water / 10...61 Hz 1 mm
MTTF[years] [years]395.9
UL approvalFile number UL
E364788
File number ULE364788
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]82.05
Housingrectangular
Dimensions[mm] [mm]90 x 30.2 x 53.7
MaterialsHousing: PPS 40% glass fibre; electronics: PC 10% glass fibre
Materials (wetted parts)sensor: PPSU; Pipe section: PPS 40% glass fibre; Sealing: EPDM
Tightening torque[Nm] [Nm]12
Process connectionthreaded connection G 3/4 external thread DN10

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection - plug

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM SV5151”

Your email address will not be published. Required fields are marked *