Fast delivery within 72 Hours

IFM SU9001

SU9001

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Precise measurement of flow, consumption and medium temperature
Suitable for water, oils and glycol solutions
For installation in pipes
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0...3170 gph
0...52.84 gpm
0...3170 gph0...52.84 gpm
Process connectionthreaded connection G 1 1/4 external thread flat seal

Application

Special featureGold-plated contacts
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediawater; glycol solutions; coolants; oils
Note on medialow-viscosity oils with viscosity: 7...40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30...68 mm²/s (40 °C)
Medium temperature[°F] [°F]14...176
Pressure rating16 bar
232 psi
1.6 MPa
16 bar232 psi

Electrical data

Operating voltage[V] [V]19...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]100
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]10
Measuring principleultrasonic

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...3170 gph
0...52.84 gpm
0...3170 gph0...52.84 gpm
Display range0...3804 gph
0...63.4 gpm
0...3804 gph0...63.4 gpm
Resolution1 gph
0.02 gpm
1 gph0.02 gpm
Set point SP7...3170 gph
0.12...52.84 gpm
7...3170 gph0.12...52.84 gpm
Reset point rP0...3163 gph
0...52.72 gpm
0...3163 gph0...52.72 gpm
Analogue start point ASP0...2547 gph
0...42.46 gpm
0...2547 gph0...42.46 gpm
Analogue end point AEP621...3170 gph
10.36...52.84 gpm
621...3170 gph10.36...52.84 gpm
Max. flow rate3804 gph
63.4 gpm
3804 gph63.4 gpm
In steps of0.02 gal
Pulse value0.02...9000 * 10³ gal
Pulse length[s] [s]0,095...2
Measuring range[°F] [°F]14...176
Resolution[°F] [°F]0.5
Set point SP[°F] [°F]14.5...176
Reset point rP[°F] [°F]14...175.5
Analogue start point[°F] [°F]14...144
Analogue end point[°F] [°F]46...176
In steps of[°F] [°F]0.5

Accuracy / deviations

Accuracy (in the measuring range)water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (8 % MW + 0,5 % MEW)
Repeatability0,05 gpm; 3 gph
Accuracy[K] [K]± 5,4 (Q > 0,26 gpm)

Response times

Response time[s] [s]0.25; (dAP = 0)
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...1
Dynamic response T05 / T09[s] [s]T09 = 30 (Q > 5 gpm); (water)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring

Operating conditions

Ambient temperature[°F] [°F]14...140
Storage temperature[°F] [°F]-13...176
ProtectionIP 67

Tests / approvals

EMCEN 61000-4-2 ESD
4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
10 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-5 Surge
0,5 kV
EN 61000-4-6 HF conducted
10 V
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge0,5 kV
EN 61000-4-6 HF conducted10 V
Shock resistanceDIN IEC 68-2-27
20 g (11 ms)
DIN IEC 68-2-2720 g (11 ms)
Vibration resistanceDIN IEC 68-2-6
5 g (10...2000 Hz)
DIN IEC 68-2-65 g (10...2000 Hz)
MTTF[years] [years]185
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]1859
Housingrectangular
Dimensions[mm] [mm]130 x 100 x 80.5
Materialshousing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA
Materials (wetted parts)Pipe section: stainless steel (316L/1.4404); Process connection sealing: NBR reinforced fibre Flat seal; FKM; PPS
Process connectionthreaded connection G 1 1/4 external thread flat seal

Displays / operating elements

DisplayDisplay unit
5 x LED, green (gpm, gph, gal, °F, 10³)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Display unit5 x LED, green (gpm, gph, gal, °F, 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Accessories

Items suppliedsealings: 2, Centellen
Accessories (optional)adapter for pipe: 1 x 1" NPT, stainless steel, E40206

Remarks

Remarkssealing: only with supplied Centellen seals
MW = measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM SU9001”

Your email address will not be published. Required fields are marked *