Description
Precise measurement of flow, consumption and medium temperature
Suitable for water, oils and glycol solutions
For installation in pipes
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Measuring range | 0...792.5 gph 0...13.21 gpm |
| 0...792.5 gph | 0...13.21 gpm |
| Process connection | threaded connection G 3/4 external thread flat seal |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | totaliser function; for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | water; glycol solutions; coolants; oils |
| Note on media | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C) high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
| Medium temperature[°F] [°F] | 14...176 |
| Pressure rating | 16 bar 232 psi 1.6 MPa |
| 16 bar | 232 psi |
Electrical data
| Operating voltage[V] [V] | 19...30 DC; (to SELV/PELV) |
|---|---|
| Current consumption[mA] [mA] | 100 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 10 |
| Measuring principle | ultrasonic |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Inputs
| Inputs | counter reset |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; pulse signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10; (scalable) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...792.5 gph 0...13.21 gpm |
|---|---|
| 0...792.5 gph | 0...13.21 gpm |
| Display range | 0...951 gph 0...15.86 gpm |
| 0...951 gph | 0...15.86 gpm |
| Resolution | 1 gph 0.02 gpm |
| 1 gph | 0.02 gpm |
| Set point SP | 1...793 gph 0.02...13.22 gpm |
| 1...793 gph | 0.02...13.22 gpm |
| Reset point rP | 0...791 gph 0...13.2 gpm |
| 0...791 gph | 0...13.2 gpm |
| Analogue start point ASP | 0...637 gph 0...10.62 gpm |
| 0...637 gph | 0...10.62 gpm |
| Analogue end point AEP | 156...793 gph 2.6...13.22 gpm |
| 156...793 gph | 2.6...13.22 gpm |
| Max. flow rate | 951 gph 15.86 gpm |
| 951 gph | 15.86 gpm |
| In steps of | 0.02 gal |
| Pulse value | 0.02...9000 * 10³ gal |
| Pulse length[s] [s] | 0,6...2 |
| Measuring range[°F] [°F] | 14...176 |
| Resolution[°F] [°F] | 0.5 |
| Set point SP[°F] [°F] | 14...176 |
| Reset point rP[°F] [°F] | 14...176 |
| Analogue start point[°F] [°F] | 14...144 |
| Analogue end point[°F] [°F] | 46...176 |
| In steps of[°F] [°F] | 0.5 |
Accuracy / deviations
| Accuracy (in the measuring range) | water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (5 % MW + 0,5 % MEW) |
|---|---|
| Repeatability | 0,025 gpm; 1,5 gph |
| Accuracy[K] [K] | ± 5,4 (Q > 0,26 gpm) |
Response times
| Response time[s] [s] | 0.25; (dAP = 0) |
|---|---|
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...1 |
| Dynamic response T05 / T09[s] [s] | T09 = 70 (Q > 1 gpm); (water) |
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
|---|
Operating conditions
| Ambient temperature[°F] [°F] | 14...140 |
|---|---|
| Storage temperature[°F] [°F] | -13...176 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV EN 61000-4-6 HF conducted 10 V |
|---|---|
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 185 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 1505.5 |
|---|---|
| Housing | rectangular |
| Dimensions[mm] [mm] | 110 x 100 x 80.5 |
| Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
| Materials (wetted parts) | Pipe section: stainless steel (316L/1.4404); Process connection sealing: NBR reinforced fibre Flat seal; FKM; PES |
| Process connection | threaded connection G 3/4 external thread flat seal |
Displays / operating elements
| Display | Display unit 5 x LED, green (gpm, gph, gal, °F, 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
|---|---|
| Display unit | 5 x LED, green (gpm, gph, gal, °F, 10³) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Accessories
| Items supplied | sealings: 2, Centellen |
|---|---|
| Accessories (optional) | adapter for pipe: 1 x 1/2" NPT, stainless steel, E40191 adapter for pipe: 1 x 1/2" NPT, brass, E40154 |
Remarks
| Remarks | MW = measured value MEW = Final value of the measuring range sealing: only with supplied Centellen seals |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM SU7001” Cancel reply

Reviews
Clear filtersThere are no reviews yet.