Magnetic-inductive flow meter (SM Foodmag series) for the food and beverage industry
Measured variables: flow rate, total volume, temperature, conductivity and fluid detection
Easy to set up thanks to app-based menu, guided installation and hygienic pushbuttons
Reduced cabling by combining supply voltage and output signals via an M12 connection
Housing design increases shock and vibration resistance
Convenient operation via buttons or parameter setting via IO-Link
Specification
Product characteristics
| Measuring range | 20...2000 l/min 1200...120000 l/h 5.5...528.5 gpm 0.32...32.96 ft/s |
|---|---|
| 20...2000 l/min | 1200...120000 l/h |
| Nominal diameter | DN65 (2 1/2“) |
| Process connection | ifm-specific device flange |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | food and beverage industry |
| Media | conductive liquids; water; hydrous media |
| Note on media | food products such as beer, milk, fruit juices, soft drinks, ketchup, yoghurt, yoghurt toppings, ice cream conductivity: ≥ 5 µS/cm |
| Medium temperature | -20...150 °C -4...302 °F |
| -20...150 °C | -4...302 °F |
| Min. burst pressure | 543.75 psi 3.75 MPa |
| 543.75 psi | 3.75 MPa |
| Pressure rating | 362.5 psi 2.5 MPa |
| 362.5 psi | 2.5 MPa |
Electrical data
| Operating voltage[V] [V] | 18...32 DC |
|---|---|
| Current consumption[mA] [mA] | 250; (24V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 5 |
| Measuring principle | magnetic-inductive |
Inputs / outputs
| Total number of inputs and outputs | 2 |
|---|
Inputs
| Inputs | OUT2 external totaliser reset |
|---|---|
| OUT2 | external totaliser reset |
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | OUT1 pulse signal; totaliser switching signal; diagnostic signal; IO-Link OUT2 analogue signal; pulse signal; totaliser switching signal; diagnostic signal |
| OUT1 | pulse signal; totaliser switching signal; diagnostic signal; IO-Link |
| OUT2 | analogue signal; pulse signal; totaliser switching signal; diagnostic signal |
| Electrical design | PNP/NPN |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (skalierbar) |
| Max. load[Ω] [Ω] | 500 |
| Resolution of analogue output | 0.38 µA |
| Number of digital outputs | 2 |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 0...10000 |
Measuring/setting range
| Measuring range | -20...150 °C -4...302 °F |
|---|---|
| 20...2000 l/min | 1200...120000 l/h |
| Display range | -20...150 °C -4...302 °F |
| -2400...2400 l/min | -144000...144000 l/h |
| Resolution | 0.01 °C 0.1 °F |
| 0.1 l/min | 100 l/h |
| Note on factory setting | 0…130 gpm |
| Analogue start point ASP | -2000...1600 l/min -120000...96000 l/h -528.4...422.72 gpm -32.8...26.24 ft/s |
| -2000...1600 l/min | -120000...96000 l/h |
| Analogue end point AEP | -1600...2000 l/min -96000...120000 l/h -422.72...528.4 gpm -26.24...32.8 ft/s |
| -1600...2000 l/min | -96000...120000 l/h |
| Low flow cut-off LFC | 0...1600 l/min 0...96000 l/h 0...422.72 gpm 0...26.24 ft/s |
| 0...1600 l/min | 0...96000 l/h |
| Pulse length[s] [s] | 0.00005...2 |
| Pulse value | 0.038...99990000 I |
| -20...150 °C | -4...302 °F |
| 0.01 °C | 0.1 °F |
| Analogue start point | -20...116 °C -4...240.8 °F |
| -20...116 °C | -4...240.8 °F |
| Analogue end point | 14...150 °C 57.2...302 °F |
| 14...150 °C | 57.2...302 °F |
| Measuring range[µS/cm] [µS/cm] | 100...100000 |
| Display range[µS/cm] [µS/cm] | 0...10000000 |
| Resolution[µS/cm] [µS/cm] | 1 |
| Analogue start point[µS/cm] [µS/cm] | 0...80000 |
| Analogue end point[µS/cm] [µS/cm] | 20000...100000 |
Accuracy / deviations
| Accuracy (under reference conditions) | with optional factory calibration (availability is being planned) ± (0,2 % MW + 2 mm/s) standard ± (0,5 % MW + 1,5 mm/s) |
|---|---|
| with optional factory calibration (availability is being planned) | ± (0,2 % MW + 2 mm/s) |
| standard | ± (0,5 % MW + 1,5 mm/s) |
| Repeatability | ± 5% MW |
| Accuracy[K] [K] | ± 1 |
| Repeatability[K] [K] | ± 0,5 |
| Accuracy (in the measuring range) | in the range of 100...20000 µS/cm ±10% MW in the range of 20000...100000 µS/cm ±20% MW |
| in the range of 100...20000 µS/cm | ±10% MW |
| in the range of 20000...100000 µS/cm | ±20% MW |
Response times
| Response time[s] [s] | < 2 |
|---|---|
| Damping process value dAP[s] [s] | 0...5 |
Software / programming
| Diagnostic functions | direction of flow detection; liquid detection |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 4.3.4 Measuring and Switching Sensor, floating point, 4 channel BLOB Binary Large Object transfer Common - I&D Identification and Diagnosis Extension Sensor Control Wide Extension Quantity detection, switches when value exceeds the setpoint Function Locator Function ProductURI |
| Smart Sensor - SSP 4.3.4 | Measuring and Switching Sensor, floating point, 4 channel |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Extension | Quantity detection, switches when value exceeds the setpoint |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 6 |
| Process data binary | 8 |
| Min. process cycle time[ms] [ms] | 1.9 |
| IO-Link process data (cyclical) | totaliser 32 flow 32 temperature 32 conductivity 32 status 4 binary switching information 8 |
| totaliser | 32 |
| flow | 32 |
| temperature | 32 |
| conductivity | 32 |
| status | 4 |
| binary switching information | 8 |
| IO-Link functions (acyclical) | direction of flow detection; totaliser; memory; operating hours counter; internal temperature; simulation function |
| Supported DeviceIDs | default 1796 |
| default | 1796 |
Operating conditions
| Ambient temperature | -20...65 °C -4...149 °F |
|---|---|
| -20...65 °C | -4...149 °F |
| Storage temperature | -20...80 °C -4...176 °F |
| -20...80 °C | -4...176 °F |
| Protection | IP 67; IP 69; (to DIN EN 60529) |
Tests / approvals
| EMC | DIN 61326-1 |
|---|---|
| CPA approval | model number SMF accuracy class 0,5 |
| model number | SMF |
| accuracy class | 0,5 |
| Shock resistance | DIN IEC 68-2-27 20 g (18ms) |
| DIN IEC 68-2-27 | 20 g (18ms) |
| Vibration resistance | DIN IEC 68-2-6 5 g (10...2000Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000Hz) |
| MTTF[years] [years] | 81 |
| UL approval | UL approval no. I031 |
| UL approval no. | I031 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 6897 |
|---|---|
| Housing | cylindrical |
| Inlet pipe length | 5 x DN |
| Outlet pipe length | 2 x DN |
| Dimensions[mm] [mm] | Ø 154 / L = 140 |
| Materials | housing: stainless steel (316L/1.4404); flange: stainless steel (304/1.4301); electronics fixture: stainless steel (304/1.4301); electronics: stainless steel (316L/1.4404); Display: polysulfone; Display-Sealing: FKM; LED ring: PP |
| Materials (wetted parts) | Pipe section: PFA; electrodes: stainless steel (316L/1.4435) |
| Nominal diameter | DN65 (2 1/2“) |
| Process connection | ifm-specific device flange |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.4 μm |
Displays / operating elements
| Display | process value full graphics TFT display, multi-colour 3,5" 320 x 240 Pixel display layouts: 4 display rotation: 4 x 90° operating status LED ring, three-colour |
|---|---|
| process value | full graphics TFT display, multi-colour 3,5" 320 x 240 Pixel |
| operating status | LED ring, three-colour |
| Display unit | l/min; l/h; hl/min; hl/h; m³/min; m³/h; m/s; gpm; gph; ft/s; °C; °F; μS/cm; S/m; ms/cm |
| Factory setting | gpm; °F; μS/cm |
| Language | German; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese |
| Operating elements | 4 capacitive pushbuttons |
| 4 | capacitive pushbuttons |
Remarks
| Remarks | MW = measured value MEW = Final value of the measuring range pulse and totaliser signal are only available for one of the two outputs reference conditions (1/2): water (free of gas bubbles), 15...35 °C, process connection: DIN32676 series A, pipe standard suitable for process connection reference conditions (2/2): inlet pipe length 10xDN, outlet pipe length 5xDN, device settling time: 30 minutes, device orientation: horizontal, display orientation: up accuracy specifications according to factory certificate on delivery |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|