Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range5...300 l/min
0.3...18 m³/h
5...300 l/min0.3...18 m³/h
Process connectionthreaded connection Rc 1 1/2 internal thread DN40

Application

Special featureGold-plated contacts
Applicationtotaliser function; empty pipe detection; for industrial applications
Mediaconductive liquids; water; hydrous media
Note on mediaconductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature[°C] [°C]-10...90
Pressure rating16 bar
1.6 MPa
16 bar1.6 MPa
MAWP for applications according to CRN8.9 bar
0.89 MPa
8.9 bar0.89 MPa

Electrical data

Operating voltage[V] [V]18...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principlemagnetic-inductive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output[Hz] [Hz]0.1...10000

Measuring/setting range

Measuring range5...300 l/min
0.3...18 m³/h
5...300 l/min0.3...18 m³/h
Display range-360...360 l/min
-21.6...21.6 m³/h
-360...360 l/min-21.6...21.6 m³/h
Resolution0.5 l/min
0.02 m³/h
0.5 l/min0.02 m³/h
Set point SP6.5...300 l/min
0.4...18 m³/h
6.5...300 l/min0.4...18 m³/h
Reset point rP5...298.5 l/min
0.3...17.9 m³/h
5...298.5 l/min0.3...17.9 m³/h
Analogue start point ASP0...240 l/min
0...14.4 m³/h
0...240 l/min0...14.4 m³/h
Analogue end point AEP60...300 l/min
3.6...18 m³/h
60...300 l/min3.6...18 m³/h
Low flow cut-off LFC< 15 l/min
< 0.9 m³/h
< 15 l/min< 0.9 m³/h
In steps of0.0001 m³
Measuring dynamics1:60
Pulse value0.0001...300 x 10³ m³
Pulse length[s] [s]0,016...2
Measuring range[°C] [°C]-20...80
Display range[°C] [°C]-40...100
Resolution[°C] [°C]0.2
Set point SP[°C] [°C]-19.2...80
Reset point rP[°C] [°C]-19.6...79.6
Analogue start point[°C] [°C]-20...60
Analogue end point[°C] [°C]0...80
In steps of[°C] [°C]0.2

Accuracy / deviations

Accuracy (in the measuring range)± (0,8 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Temperature drift± 0,0333 °C / K
Accuracy[K] [K]± 1 (25 °C; Q > 15 l/min)

Response times

Response time[s] [s]0.35; (dAP = 0)
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 3 (Q > 15 l/min)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesSmart Sensor - SSP 0
Generic Profiled Sensor
Function
Device identification
Function
Process data variable
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionProcess data variable
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]5
Supported DeviceIDsdefault
391
default391

Operating conditions

Ambient temperature[°C] [°C]-10...60
Storage temperature[°C] [°C]-25...80
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
CPA approvalmodel number
003MI
accuracy class
-
maximum allowable error
± 1,5 % FS
Q (min)
0,3 m³/h
Q (t)
-
Q (max)
18 m³/h
Medium temperature
-10...70°C
model number003MI
accuracy class-
maximum allowable error± 1,5 % FS
Q (min)0,3 m³/h
Q (t)-
Q (max)18 m³/h
Medium temperature-10...70°C
Shock resistanceDIN EN 60068-2-27
20 g (11 ms)
DIN EN 60068-2-2720 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
5 g (10...2000 Hz)
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF[years] [years]85
UL approvalUL approval no.
I008
UL approval no.I008
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]2751
Housingrectangular
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]170 x 103 x 117
Materialsstainless steel (316L/1.4404); stainless steel (316Ti/1.4571); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (316L/1.4404); stainless steel (316Ti/1.4571); PEEK; EPDM
Process connectionthreaded connection Rc 1 1/2 internal thread DN40

Displays / operating elements

DisplayDisplay unit
6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Accessories

Items suppliedLabel

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated