Fast delivery within 72 Hours

IFM SM8601

SM8601

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range6...1584 gph
0.1...26.4 gpm
6...1584 gph0.1...26.4 gpm
Process connectionthreaded connection 1" NPT internal thread DN25

Application

Special featureGold-plated contacts
Applicationtotaliser function; for industrial applications
Mediaconductive liquids; water; hydrous media
Note on mediaconductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature[°F] [°F]14...158
Pressure rating16 bar
232 psi
1.6 MPa
16 bar232 psi
MAWP for applications according to CRN10.4 bar
1.04 MPa
10.4 bar1.04 MPa

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principlemagnetic-inductive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]200
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range6...1584 gph
0.1...26.4 gpm
6...1584 gph0.1...26.4 gpm
Display range-1902...1902 gph
-31.7...31.7 gpm
-1902...1902 gph-31.7...31.7 gpm
Resolution2 gph
0.05 gpm
2 gph0.05 gpm
Set point SP14...1586 gph
0.25...26.4 gpm
14...1586 gph0.25...26.4 gpm
Reset point rP6...1578 gph
0.1...26.25 gpm
6...1578 gph0.1...26.25 gpm
Analogue start point ASP0...1272 gph
0...21.2 gpm
0...1272 gph0...21.2 gpm
Analogue end point AEP312...1586 gph
5.2...26.4 gpm
312...1586 gph5.2...26.4 gpm
In steps of2 gph
0.05 gpm
Pulse value0.01...100 000 000 gal
Pulse length[s] [s]0,0025...2
Measuring range[°F] [°F]-4...176
Resolution[°F] [°F]0.5
Set point SP[°F] [°F]-2.5...176
Reset point rP[°F] [°F]-3.5...175
Analogue start point[°F] [°F]-4...140.5
Analogue end point[°F] [°F]31.5...176
In steps of[°F] [°F]0.5

Accuracy / deviations

Accuracy (in the measuring range)± (0,8 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Accuracy[K] [K]± 2,5 (Q > 0,26 gpm)

Response times

Response time[s] [s]0.15; (dAP = 0, T19)
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 20 (Q > 0,26 gpm)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0
Generic Profiled Sensor
Function
Device identification
Function
Process data variable
Function
Device diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]5
Supported DeviceIDsdefault
576
default576

Operating conditions

Ambient temperature[°F] [°F]14...140
Storage temperature[°F] [°F]-13...176
ProtectionIP 67

Tests / approvals

EMCDIN EN 60947-5-9
Shock resistanceDIN EN 60068-2-27
20 g (11 ms)
DIN EN 60068-2-2720 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
5 g (10...2000 Hz)
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF[years] [years]145
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]698.5
Housingcylindrical
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]Ø 54 / L = 110
Materialsstainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (316L/1.4404); PEEK; FKM
Process connectionthreaded connection 1" NPT internal thread DN25

Displays / operating elements

DisplayDisplay unit
6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM SM8601”