Description
Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display
Convenient operation via buttons or parameter setting via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Measuring range | 1.5...396 gph 0.03...6.6 gpm |
| 1.5...396 gph | 0.03...6.6 gpm |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | totaliser function; for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | conductive liquids; water; hydrous media |
| Note on media | conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) |
| Medium temperature[°F] [°F] | 14...158 |
| Pressure rating | 16 bar 232 psi 1.6 MPa |
| 16 bar | 232 psi |
| MAWP for applications according to CRN | 15.3 bar 1.53 MPa |
| 15.3 bar | 1.53 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
|---|---|
| Current consumption[mA] [mA] | 95; (24 V) |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 5 |
| Measuring principle | magnetic-inductive |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Inputs
| Inputs | counter reset |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10; (scalable) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 1.5...396 gph 0.03...6.6 gpm |
|---|---|
| 1.5...396 gph | 0.03...6.6 gpm |
| Display range | -475.5...475.5 gph -7.925...7.925 gpm |
| -475.5...475.5 gph | -7.925...7.925 gpm |
| Resolution | 0.5 gph 0.01 gpm |
| 0.5 gph | 0.01 gpm |
| Set point SP | 3.5...396.5 gph 0.06...6.6 gpm |
| 3.5...396.5 gph | 0.06...6.6 gpm |
| Reset point rP | 1.5...394 gph 0.03...6.57 gpm |
| 1.5...394 gph | 0.03...6.57 gpm |
| Analogue start point ASP | 0...318 gph 0...5.3 gpm |
| 0...318 gph | 0...5.3 gpm |
| Analogue end point AEP | 78...396 gph 1.3...6.6 gpm |
| 78...396 gph | 1.3...6.6 gpm |
| In steps of | 0.5 gph 0.01 gpm |
| Pulse value | 0.01...30 000 000 gal |
| Pulse length[s] [s] | 0,01...2 |
| Measuring range[°F] [°F] | -4...176 |
| Resolution[°F] [°F] | 0.1 |
| Set point SP[°F] [°F] | -2.5...176 |
| Reset point rP[°F] [°F] | -3.5...175 |
| Analogue start point[°F] [°F] | -4...140.5 |
| Analogue end point[°F] [°F] | 31.5...176 |
| In steps of[°F] [°F] | 0.5 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
|---|---|
| Repeatability | ± 0,2% MEW |
| Accuracy[K] [K] | ± 2,5 (Q > 0,26 gpm) |
Response times
| Response time[s] [s] | 0.15; (dAP = 0, T19) |
|---|---|
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 20 (Q > 0,26 gpm) |
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0 Generic Profiled Sensor Function Device identification Function Process data variable Function Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 3 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 5 |
| Supported DeviceIDs | default 570 |
| default | 570 |
Operating conditions
| Ambient temperature[°F] [°F] | 14...140 |
|---|---|
| Storage temperature[°F] [°F] | -13...176 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
|---|---|
| Shock resistance | DIN IEC 68-2-27 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 160 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 546 |
|---|---|
| Housing | cylindrical |
| Inlet pipe length | 3 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions[mm] [mm] | Ø 54 / L = 110 |
| Materials | stainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (316L/1.4404); PEEK; FKM |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
Displays / operating elements
| Display | Display unit 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
|---|---|
| Display unit | 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | MW = measured value MEW = Final value of the measuring range |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|