Fast delivery within 72 Hours

IFM SD8500

SD8500

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Precise measurement of flow, consumption, pressure and medium temperature
High accuracy, repeatability and measurement dynamics
For detecting compressed air in industrial use
Red/green display for clear identification of the acceptable range
Display can be rotated for optimum alignment
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range14...3750 l/min
0.4...103.7 m/s
0.8...225 m³/h
14...3750 l/min0.4...103.7 m/s
Process connectionthreaded connection R 1 external thread DN25

Application

Applicationfor industrial applications
Mediacompressed air
Medium temperature[°C] [°C]-10...60
Min. burst pressure64 bar
6.4 MPa
64 bar6.4 MPa
Pressure rating16 bar
1.6 MPa
16 bar1.6 MPa
MAWP for applications according to CRN[bar] [bar]10.5

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-10...60 °C
14...140 °F
14...3750 l/min0.4...103.7 m/s
Display range-24...74 °C
-11.2...165.2 °F
0...4500 l/min0...124.4 m/s
Resolution0.2 °C
0.5 °F
2 l/min0.1 m/s
Set point SP-9.7...60 °C
14.6...140 °F
32...3749 l/min0.9...103.7 m/s
Reset point rP-10...59.7 °C
14...139.4 °F
14...3730 l/min0.4...103.2 m/s
Analogue start point ASP0...3000 l/min
0...83 m/s
0...180 m³/h
0...3000 l/min0...83 m/s
Analogue end point AEP750...3750 l/min
20.7...103.7 m/s
45...225 m³/h
750...3750 l/min20.7...103.7 m/s
Low flow cut-off LFC4...40 l/min
0.1...1.1 m/s
0.3...2.4 m³/h
4...40 l/min0.1...1.1 m/s
In steps of0.1 °C
0.1 °F
1 l/min0.1 m/s
Measuring range[bar] [bar]-1...16
Display range[bar] [bar]-1...20
Resolution[bar] [bar]0.05
Set point SP[bar] [bar]-0.92...16
Reset point rP[bar] [bar]-1...15.92
Analogue start point[bar] [bar]-1...12.8
Analogue end point[bar] [bar]2.2...16
In steps of[bar] [bar]0.01
0...100000000 m³0...353146667.2 scf
0.001...10000000 m³0.05...353146667.2 scf
Pulse value0.001...10000000 m³
0.05...353146667.2 scf
0.0001 m³0.005 scf
Pulse length[s] [s]0.007...2
-10...60 °C14...140 °F
-24...74 °C-11.2...165.2 °F
0.2 °C0.5 °F
-9.7...60 °C14.6...140 °F
-10...59.7 °C14...139.4 °F
Analogue start point-10...46 °C
14...114.8 °F
-10...46 °C14...114.8 °F
Analogue end point4...60 °C
39.2...140 °F
4...60 °C39.2...140 °F
0.1 °C0.1 °F

Accuracy / deviations

Temperature coefficient[1/K] [1/K]± 0,07 % MW
Accuracy (in the measuring range)class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C
Repeatability± (0,4 % MW + 0,1 % MEW)
Repeatability[% of the final value] [% of the final value]± 0,2
Characteristics deviation[% of the final value] [% of the final value]< ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span[% MEW / 10 K] [% MEW / 10 K]± 0,3
Greatest TEMPCO of the zero point[% MEW / 10 K] [% MEW / 10 K]± 0,1
Accuracy[K] [K]± 0,5; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.05
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 0,5

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesCommon - I&D
Identification and Diagnosis
Function
Measurement data, standard resolution
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO modeyes
Required master port typeA
Process data analogue8
Process data binary2
Min. process cycle time[ms] [ms]7.2
Supported DeviceIDsdefault
866
default866

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
CPA approvalmodel number
001TG
accuracy class
-
maximum allowable error
± 2,5 % FS
Q (min)
0,8 m³/h
Q (t)
-
Q (max)
225 m³/h
model number001TG
accuracy class-
maximum allowable error± 2,5 % FS
Q (min)0,8 m³/h
Q (t)-
Q (max)225 m³/h
Vibration resistanceDIN EN 68000-2-6
5 g (10...2000 Hz)
DIN EN 68000-2-65 g (10...2000 Hz)
MTTF[years] [years]183
UL approvalUL approval no.
I012
File number UL
E174189
UL approval no.I012
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for stable gases fluid group 2

Mechanical data

Weight[g] [g]1598.5
Housingrectangular
Dimensions[mm] [mm]475 x 45.4 x 83.1
MaterialsPBT+PC-GF30; PPS GF40; stainless steel (304/1.4301); stainless steel (303/1.4305); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts)stainless steel (304/1.4301); stainless steel (303/1.4305); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connectionthreaded connection R 1 external thread DN25

Displays / operating elements

Displaycolour display 1,44", 128 x 128 pixels
2 x LED, yellow

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM SD8500”

Your email address will not be published. Required fields are marked *