Description

Precise measurement of flow, consumption, pressure and medium temperature
High accuracy, repeatability and measurement dynamics
For the detection of helium
Red/green display for clear identification of the acceptable range
Display can be rotated for optimum alignment
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0.8...83.4 l/min
0.3...27.6 m/s
0.05...5 m³/h
0.8...83.4 l/min0.3...27.6 m/s
Process connectionthreaded connection G 1/4 internal thread DN8

Application

Applicationfor industrial applications
Mediahelium
Medium temperature[°C] [°C]-10...60
Min. burst pressure[bar] [bar]64
Pressure rating16 bar
1.6 MPa
16 bar1.6 MPa
MAWP for applications according to CRN[bar] [bar]9.5

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-10...60 °C
14...140 °F
0.8...83.4 l/min0.3...27.6 m/s
Display range-24...74 °C
-11.2...165.2 °F
0...100 l/min0...33.1 m/s
Resolution0.2 °C
0.5 °F
0.2 l/min0.1 m/s
Set point SP-9.7...60 °C
14.6...140 °F
1.3...83.3 l/min0.4...27.6 m/s
Reset point rP-10...59.7 °C
14...139.4 °F
0.9...82.9 l/min0.3...27.5 m/s
Analogue start point ASP0...66.6 l/min
0...22.1 m/s
0...4 m³/h
0...66.6 l/min0...22.1 m/s
Analogue end point AEP16.7...83.3 l/min
5.5...27.6 m/s
1...5 m³/h
16.7...83.3 l/min5.5...27.6 m/s
Low flow cut-off LFC0.6...0.8 l/min
0.2...0.3 m/s
0.04...0.05 m³/h
0.6...0.8 l/min0.2...0.3 m/s
In steps of0.1 °C
0.1 °F
0.1 l/min0.1 m/s
Measuring range[bar] [bar]-1...16
Display range[bar] [bar]-1...20
Resolution[bar] [bar]0.05
Set point SP[bar] [bar]-0.92...16
Reset point rP[bar] [bar]-1...15.92
Analogue start point[bar] [bar]-1...12.8
Analogue end point[bar] [bar]2.2...16
In steps of[bar] [bar]0.01
0...100000000 m³0...353146667.2 scf
0.001...10000000 m³0.05...353146667.2 scf
Pulse value0.001...10000000 m³
0.05...353146667.2 scf
0.0001 m³0.005 scf
Pulse length[s] [s]0.01...2
-10...60 °C14...140 °F
-24...74 °C-11.2...165.2 °F
0.2 °C0.5 °F
-9.7...60 °C14.6...140 °F
-10...59.7 °C14...139.4 °F
Analogue start point-10...46 °C
14...114.8 °F
-10...46 °C14...114.8 °F
Analogue end point4...60 °C
39.2...140 °F
4...60 °C39.2...140 °F
0.1 °C0.1 °F

Accuracy / deviations

Temperature coefficient[1/K] [1/K]± 0,07 % MW
Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); at medium temperature 23 °C
Repeatability0,8 % MW + 0,2 % MEW
Repeatability[% of the final value] [% of the final value]± 0,2
Characteristics deviation[% of the final value] [% of the final value]< ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span[% MEW / 10 K] [% MEW / 10 K]± 0,15
Greatest TEMPCO of the zero point[% MEW / 10 K] [% MEW / 10 K]± 0,25
Accuracy[K] [K]± 0,5; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.05
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 0,5

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesCommon - I&D
Identification and Diagnosis
Function
Measurement data, standard resolution
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO modeyes
Required master port typeA
Process data analogue8
Process data binary2
Min. process cycle time[ms] [ms]7.2
Supported DeviceIDsdefault
1301
default1301

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
CPA approvalmodel number
003TG
accuracy class
-
maximum allowable error
± 7 % FS
Q (min)
0,05 m³/h (He)
Q (t)
-
Q (max)
5 m³/h (He)
model number003TG
accuracy class-
maximum allowable error± 7 % FS
Q (min)0,05 m³/h (He)
Q (t)-
Q (max)5 m³/h (He)
Vibration resistanceDIN EN 68000-2-6
5 g (10...2000 Hz)
DIN EN 68000-2-65 g (10...2000 Hz)
MTTF[years] [years]180
UL approvalUL approval no.
I012
File number UL
E174189
UL approval no.I012
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for stable gases fluid group 2

Mechanical data

Weight[g] [g]554
Housingrectangular
Dimensions[mm] [mm]182 x 45.4 x 67.8
MaterialsPBT+PC-GF30; PPS GF40; stainless steel (304/1.4301); stainless steel (303/1.4305); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts)EN AW-6082 (aluminium); stainless steel (303/1.4305); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connectionthreaded connection G 1/4 internal thread DN8

Displays / operating elements

Displaycolour display 1,44", 128 x 128 pixels
2 x LED, yellow

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range
Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity
For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM SD5800”

Your email address will not be published. Required fields are marked *