Precise detection of flow and medium temperature
Suitable for water, coolants, oil and glycol solutions thanks to integrated measurement graphs
Very fast response time (~10 ms)
With switching output, analogue output or frequency output and IO-Link
Clearly visible LED display with red/green colour change
Convenient operation via buttons or parameter setting via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Measuring range | 4...200 l/min 0.24...12 m³/h |
| 4...200 l/min | 0.24...12 m³/h |
| Process connection | threaded connection Rp 1 1/2 internal thread |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | for industrial applications |
| Media | Liquids; water; glycol solutions; coolants |
| Note on media | oil 1 with viscosity: 10 mm²/s (40 °C) oil 2 with viscosity: 46 mm²/s (40 °C) |
| Medium temperature[°C] [°C] | -10...100 |
| Pressure rating | 25 bar 2.5 MPa |
| 25 bar | 2.5 MPa |
| MAWP for applications according to CRN[bar] [bar] | 25 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
|---|---|
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C)) |
| Switching cycles (mechanical) | 10 million |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output[Hz] [Hz] | 0...10000 |
Measuring/setting range
| Measuring range | 4...200 l/min 0.24...12 m³/h |
|---|---|
| 4...200 l/min | 0.24...12 m³/h |
| Display range | 0...240 l/min 0...14.4 m³/h |
| 0...240 l/min | 0...14.4 m³/h |
| Resolution | 1 l/min 0.05 m³/h |
| 1 l/min | 0.05 m³/h |
| Set point SP | 2...200 l/min 0.1...12 m³/h |
| 2...200 l/min | 0.1...12 m³/h |
| Reset point rP | 0...198 l/min 0...11.9 m³/h |
| 0...198 l/min | 0...11.9 m³/h |
| Frequency end point, FEP | 13...200 l/min 0.8...12 m³/h |
| 13...200 l/min | 0.8...12 m³/h |
| In steps of | 1 l/min 0.05 m³/h |
| Frequency at the end point FRP[Hz] [Hz] | 10...10000 |
| In steps of[Hz] [Hz] | 10 |
| Measuring dynamics | 1:50 |
| Measuring range[°C] [°C] | -10...100 |
| Display range[°C] [°C] | -32...122 |
| Resolution[°C] [°C] | 1 |
| Set point SP[°C] [°C] | -9...100 |
| Reset point rP[°C] [°C] | -10...99 |
| In steps of[°C] [°C] | 1 |
| Frequency start point, FSP[°C] [°C] | -10...78 |
| Frequency end point, FEP[°C] [°C] | 12...100 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 1 l/min; medium and operating temperature: +22 °C ± 4K) |
|---|---|
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,029 °C / K |
| Accuracy[K] [K] | 3 K (25°C; Q > 1 l/min) |
Response times
| Response time[s] [s] | 0.01 |
|---|---|
| Damping process value dAP[s] [s] | 0...5 |
| Damping for the analogue output dAA[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 120 (Q > 1 l/min) |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0 Generic Profiled Sensor Function Device identification Function Process data variable Function Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default 564 |
| default | 564 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
|---|---|
| Note on ambient temperature | medium temperature < 80 °C medium temperature < 100 °C: 0...40 °C |
| Storage temperature[°C] [°C] | -15...80 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 20 g (11 ms) |
| DIN EN 60068-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 5 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 145 |
| UL approval | UL approval no. I007 File number UL E174189 |
| UL approval no. | I007 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 2234.1 |
|---|---|
| Materials | stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts) | stainless steel (316 / 1.4401); stainless steel (316L/1.4404); brass (2.0371); brass chemically nickel-plated; PPS; PP-GF30; spacer: POM; O-ring: FKM |
| Process connection | threaded connection Rp 1 1/2 internal thread |
Displays / operating elements
| Display | Display unit 3 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit programming alphanumeric display, 4-digit |
|---|---|
| Display unit | 3 x LED, green |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | Recommendation: use a 200-micron filter. All data refer to water (20 °C). MW = measured value MEW = Final value of the measuring range |
|---|---|
| Notes | Please note the changed housing design! |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|