Fast delivery within 72 Hours
IFM SBN246
SBN246
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Precise detection of flow in pipes
Suitable for water, oils and glycol solutions
Precise linearized analogue output
Robust housing with very high pressure rating
Lifespan of more than 10 million pressure cycles
Convenient operation via buttons or parameter setting via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Measuring range[gph] [gph] | 30...1620 |
| Process connection | threaded connection 1" NPT internal thread |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | for industrial applications |
| Media | Liquids; water; glycol solutions; coolants |
| Note on media | oil 1 with viscosity: 10 mm²/s (104 °F) oil 2 with viscosity: 46 mm²/s (104 °F) |
| Medium temperature[°F] [°F] | 14...212 |
| Pressure rating | 25 bar 2.5 MPa |
| 25 bar | 2.5 MPa |
| MAWP for applications according to CRN[bar] [bar] | 25 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
|---|---|
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F)) |
| Switching cycles (mechanical) | 10 million |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output[Hz] [Hz] | 0...10000 |
Measuring/setting range
| Measuring range[gph] [gph] | 30...1620 |
|---|---|
| Display range | 0...1940 gph 0...32.4 gpm |
| 0...1940 gph | 0...32.4 gpm |
| Resolution | 10 gph 0.1 gpm |
| 10 gph | 0.1 gpm |
| Set point SP | 10...1620 gph 0.2...27 gpm |
| 10...1620 gph | 0.2...27 gpm |
| Reset point rP | 0...1610 gph 0...26.8 gpm |
| 0...1610 gph | 0...26.8 gpm |
| Frequency end point, FEP | 110...1620 gph 1.8...27 gpm |
| 110...1620 gph | 1.8...27 gpm |
| In steps of | 10 gph 0.1 gpm |
| Frequency at the end point FRP[Hz] [Hz] | 10...10000 |
| Measuring dynamics | 1:50 |
| Measuring range[°F] [°F] | 14...212 |
| Display range[°F] [°F] | -26...252 |
| Resolution[°F] [°F] | 2 |
| Set point SP[°F] [°F] | 16...212 |
| Reset point rP[°F] [°F] | 14...210 |
| In steps of[°F] [°F] | 2 |
| Frequency start point, FSP[°F] [°F] | 14...172 |
| Frequency end point, FEP[°F] [°F] | 54...212 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 2 l/min; medium and operating temperature: +71,6 °F ± 4K) |
|---|---|
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,9802 °F / K |
| Accuracy[K] [K] | 3 K (77 °F; Q > 1 l/min) |
Response times
| Response time[s] [s] | 0.01 |
|---|---|
| Damping process value dAP[s] [s] | 0...5 |
| Damping for the analogue output dAA[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 120 (Q > 1 l/min) |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0 Generic Profiled Sensor Function Device identification Function Process data variable Function Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default 568 |
| default | 568 |
Operating conditions
| Ambient temperature[°F] [°F] | 32...140 |
|---|---|
| Note on ambient temperature | medium temperature < 176 °F medium temperature < 212 °F: 32...104 °F |
| Storage temperature[°F] [°F] | 5...176 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 20 g (11 ms) |
| DIN EN 60068-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 5 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 145 |
| UL approval | UL approval no. I006 File number UL E174189 |
| UL approval no. | I006 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 1292.4 |
|---|---|
| Materials | stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts) | stainless steel (316 / 1.4401); stainless steel (316L/1.4404); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Process connection | threaded connection 1" NPT internal thread |
Displays / operating elements
| Display | Display unit 3 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit programming alphanumeric display, 4-digit |
|---|---|
| Display unit | 3 x LED, green |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | Recommendation: use a 200-micron filter. All data refer to water (68 °F). MW = measured value MEW = Final value of the measuring range |
|---|---|
| Notes | Please note the changed housing design! |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM SBN246” Cancel reply