Fast delivery within 72 Hours

IFM PY9170

PY9170

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Suited for use in homogeniser processes
Programmable switching output with IO-Link and scalable analogue output
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0...600 bar
0...8700 psi
0...60 MPa
0...600 bar0...8700 psi
Process connectionhomogeniser connection

Application

Special featureGold-plated contacts
Measuring elementdiaphragm seal
Applicationflush mountable for the food and beverage industry
Medialiquids and gases
Medium temperature[°C] [°C]5...90; (for further details see section Diagrams and graphs)
Min. burst pressure1000 bar
14500 psi
100 MPa
1000 bar14500 psi
Pressure rating800 bar
11603 psi
80 MPa
800 bar11603 psi
Note on pressure ratingtake into account the pressure resistance of the screws and seals used
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]< 500
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable 1:5)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable 1:5)
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...600 bar
0...8700 psi
0...60 MPa
0...600 bar0...8700 psi
Analogue start point0...480 bar
0...6960 psi
0...48 MPa
0...480 bar0...6960 psi
Analogue end point120...600 bar
1740...8700 psi
12...60 MPa
120...600 bar1740...8700 psi
Set point SP4...600 bar
55...8702 psi
0...60 MPa
4...600 bar55...8702 psi
Reset point rP1...597 bar
19...8666 psi
0...60 MPa
1...597 bar19...8666 psi
Min. difference between SP and rP3 bar
37 psi
1 MPa
3 bar37 psi
In steps of1 bar
1 psi
1 MPa
1 bar1 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 1; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Hysteresis deviation[% of the span] [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span] [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,2; (5...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,2; (5...80 °C)

Response times

Response time[ms] [ms]< 1.5
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...4
Damping for the analogue output dAA[s] [s]0...4
Max. response time analogue output[ms] [ms]3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 3.1
Measuring Sensor
Common - I&D
Identification and Diagnosis
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Min. process cycle time[ms] [ms]3
Supported DeviceIDsStatus_B High Resolution / CMPT = 3
637
Status_B High Resolution / CMPT = 3637
NoteFor further information please see the IODD PDF file under "Downloads"
IO-Link resolution pressure[bar] [bar]0.2
IO-Link process data (cyclical)pressure
16
device status
4
binary switching information
2
pressure16
binary switching information2
IO-Link functions (acyclical)application specific tag
device status4

Operating conditions

Ambient temperature[°C] [°C]5...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
10 g (10...2000 Hz)
DIN EN 60068-2-610 g (10...2000 Hz)
MTTF[years] [years]146

Mechanical data

Weight[g] [g]1444.2
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 197
Materialsstainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); stainless steel (316L/1.4435); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4435)
Min. pressure cycles60 million
Process connectionhomogeniser connection

Displays / operating elements

DisplayDisplay unit
3 x LED, green (bar, psi, MPa)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PY9170”