Two switching outputs, one of them programmable as analogue output
Precise scalable analogue output and high precision over the whole temperature range
Clearly visible 4-digit LED display
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Measuring range[psi] [psi] | -15...15 |
| Process connection | threaded connection 1/4" NPT internal thread |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...80 |
| Min. burst pressure | 725 psi 5 MPa |
| 725 psi | 5 MPa |
| Pressure rating | 290 psi 2 MPa |
| 290 psi | 2 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; (to SELV/PELV) |
|---|---|
| Current consumption[mA] [mA] | < 35 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | < 500 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable 1:4) |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Analogue voltage output[V] [V] | 0...10; (scalable 1:4) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range[psi] [psi] | -15...15 |
|---|---|
| Set point SP[psi] [psi] | -14.8...15 |
| Reset point rP[psi] [psi] | -14.9...14.9 |
| Analogue start point[psi] [psi] | -15...7.5 |
| Analogue end point[psi] [psi] | -7.5...15 |
| In steps of[psi] [psi] | 0.1 |
| Factory setting | SP1 = -7.5 psi rP1 = -8.1 psi SP2 = 7.5 psi rP2 = 6.9 psi ASP = -15 psi AEP = 15 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,4; (Turn down 1:1) |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (-25...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (-25...80 °C) |
Response times
| Response time[ms] [ms] | < 1.5 |
|---|---|
| Damping process value dAP[s] [s] | 0.01...4 |
| Damping for the analogue output dAA[s] [s] | 0.01...4 |
| Max. response time analogue output[ms] [ms] | 3 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
|---|
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65 |
Tests / approvals
| EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 167.14 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 256.5 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 91.5 |
| Materials | stainless steel (304/1.4301); stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection 1/4" NPT internal thread |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | Display unit 3 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
|---|---|
| Display unit | mbar; kPa; psi; inH2O; inHg |
| switching status | 2 x LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|