Fast delivery within 72 Hours

IFM PX3223

PX3223

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Reliable detection of system pressure in industrial and mobile applications
Precise analogue output
With long-term stability thanks to high overload protection
Lifespan of more than 100 million pressure cycles
High shock and vibration resistance

Specification

Product characteristics

Number of inputs and outputsNumber of analogue outputs: 1
Measuring range0...500 psi
0...3450 kPa
0...500 psi0...3450 kPa
Process connectionthreaded connection 1/4" NPT external thread internal thread:M5

Application

Special featureGold-plated contacts
Applicationfor industrial applications
Medialiquids and gases
Conditionally suitable foruse in gases at pressures > 25 bar only on request
Medium temperature[°C] [°C]-25...90
Min. burst pressure5075 psi
35 MPa
5075 psi35 MPa
Pressure rating2175 psi
15 MPa
2175 psi15 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]9.6...32 DC
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes

Inputs / outputs

Number of inputs and outputsNumber of analogue outputs: 1

Outputs

Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA)
Overload protectionyes

Measuring/setting range

Measuring range0...500 psi
0...3450 kPa
0...500 psi0...3450 kPa

Accuracy / deviations

Repeatability[% of the span] [% of the span]< 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,35 (BFSL) / < ± 0,75 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,2; (0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,3; (0...80 °C)

Response times

Step response time analogue output[ms] [ms]3

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65

Tests / approvals

EMCEN 61000-4-2 ESD
4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
30 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-6 HF conducted
10 V
radiation of interference
according to the automotive directive 2004/104/EC / CISPR 25
immunity
according to the automotive directive 2004/104/EC / ISO 11452-2
HF radiated
100 V/m
pulse resistance
ISO 7637-2 / severity level 3
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated30 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
radiation of interferenceaccording to the automotive directive 2004/104/EC / CISPR 25
immunityaccording to the automotive directive 2004/104/EC / ISO 11452-2
HF radiated100 V/m
pulse resistanceISO 7637-2 / severity level 3
Shock resistanceDIN IEC 68-2-27
50 g (11 ms)
DIN IEC 68-2-2750 g (11 ms)
Vibration resistanceDIN IEC 68-2-6
20 g (10...2000 Hz)
DIN IEC 68-2-620 g (10...2000 Hz)
MTTF[years] [years]555
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]213.5
Housingcylindrical
Dimensions[mm] [mm]Ø 30 / L = 79.5
Materialsstainless steel (316L/1.4404); FKM; PA; EPDM/X
Materials (wetted parts)stainless steel (303/1.4305); ceramics; FKM
Min. pressure cycles100 million
Process connectionthreaded connection 1/4" NPT external thread internal thread:M5
Restrictor element integratedno (can be retrofitted)

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PX3223”

Your email address will not be published. Required fields are marked *