Description
Compact housing for use where space is restricted
Very high overpressure and vacuum resistance
Robust stainless steel housing with high shock and vibration resistance
Lifespan of more than 60 million pressure cycles
Two programmable switching outputs, one of them with IO-Link communication interface
User-friendly communication and parameterisation via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Measuring range | 0...100 bar 0...1450 psi 0...10 MPa |
| 0...100 bar | 0...1450 psi |
| Process connection | threaded connection G 1/8 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Application
| Measuring element | metallic thin film cell |
|---|---|
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -40...90 |
| Min. burst pressure | 1000 bar 14500 psi 100 MPa |
| 1000 bar | 14500 psi |
| Pressure rating | 250 bar 3625 psi 25 MPa |
| 250 bar | 3625 psi |
| Note on pressure rating | static |
| Vacuum resistance | -1000 mbar -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
|---|---|
| Current consumption[mA] [mA] | < 15 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...100 bar 0...1450 psi 0...10 MPa |
|---|---|
| 0...100 bar | 0...1450 psi |
| Set point SP | 1...100 bar 15...1450 psi 0.1...10 MPa |
| 1...100 bar | 15...1450 psi |
| Reset point rP | 0.5...99.5 bar 7...1433 psi 0.05...9.95 MPa |
| 0.5...99.5 bar | 7...1433 psi |
| In steps of | 0.05 bar 1 psi 0.005 MPa |
| 0.05 bar | 1 psi |
| Factory setting | SP1 = 65 bar rP1 = 60 bar ou1 = Hno; SP2 = 4 bar rP2 = 2 bar ou2 = Hnc; dS1/dS2 = 0 ms dr1/dr2 = 0 ms coF = 0 % P-n = PnP dAP= 60 ms |
| SP1 = 65 bar | rP1 = 60 bar |
| SP2 = 4 bar | rP2 = 2 bar |
| dS1/dS2 = 0 ms | dr1/dr2 = 0 ms |
| coF = 0 % | P-n = PnP |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 (nach DIN EN 61298-2) |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,05; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,1 (BFSL) / < ± 0,2 (LS) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,2 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Response times
| Response time[ms] [ms] | < 3 |
|---|
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0 Generic Profiled Sensor Function Device identification Function Process data variable Function Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 5 |
| Supported DeviceIDs | default 1565 |
| default | 1565 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...90 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | DIN EN 61326-1 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 500 g (1 ms) |
| DIN EN 60068-2-27 | 500 g (1 ms) |
| Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 667 |
| UL approval | UL approval no. J016 File number UL E174189 |
| UL approval no. | J016 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 55.5 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 19 / L = 65 |
| Materials | stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PEI |
| Materials (wetted parts) | stainless steel (303/1.4305); stainless steel (630/1.4542/17-4 PH) |
| Min. pressure cycles | 60 million; (at 1.2 times nominal pressure) |
| Tightening torque[Nm] [Nm] | 20...25; (recommended tightening torque; depends on the lubrication, the seal and the pressure load) |
| Process connection | threaded connection G 1/8 external thread (DIN EN ISO 1179-2); internal thread:M5 |
| Process connection sealing | FKM (DIN EN ISO 1179-2) |
| Restrictor element integrated | yes |
Remarks
| Remarks | BFSL = Best Fit Straight Line LS = limit value setting |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0