Fast delivery within 72 Hours

IFM PS308A

PS308A

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

For level measurement in hazardous areas
Longitudinally watertight cable
Robust stainless steel housing with high ingress resistance
High overall accuracy and long-term stability

Specification

Product characteristics

Number of inputs and outputsNumber of analogue outputs: 1
Measuring range0...0.25 bar
0...250 mbar
0...3.63 psi
0...100.4 inH2O
0...25 kPa
0...0.25 bar0...250 mbar

Application

Applicationfor industrial applications
MediaLiquids
Medium temperature[°C] [°C]-10...60; (T6: -10...60 °C; T5: -10...80 °C; T4: -10...85 °C; 1 D, 1/2 D, 2 D (750 mW): -10...40 °C; (650 mW): -10...70 °C; (550 mW): -10...85 °C)
Min. burst pressure2.4 bar
35 psi
240 kPa
2.4 bar35 psi
Pressure rating2 bar
29 psi
200 kPa
2 bar29 psi
Type of pressurerelative pressure

Electrical data

Switching amplifiersconnection to intrinsically safe supply isolators (Ex ia)
Operating voltage[V] [V]10...30 DC
Protection classIII
Reverse polarity protectionyes

Inputs / outputs

Number of inputs and outputsNumber of analogue outputs: 1

Outputs

Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]700; (Ub = 24 V; (Ub - 10 V) / 20 mA)
Short-circuit protectionyes

Measuring/setting range

Measuring range0...0.25 bar
0...250 mbar
0...3.63 psi
0...100.4 inH2O
0...25 kPa
0...0.25 bar0...250 mbar

Accuracy / deviations

Repeatability[% of the span] [% of the span]< 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< 0,25 (BFSL) / 0,5; (incl. linearity, zero and span error (limit value setting); BFSL = Best Fit Straight Line)
Linearity deviation[% of the span] [% of the span]< 0,2 (BFSL)
Long-term stability[% of the span] [% of the span]< 0,2; (per year)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (0...50 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (0...50 °C)

Operating conditions

Ambient temperature[°C] [°C]-10...60
Note on ambient temperatureT6: -10...60 °C
T5: -10...80 °C
T4: -10...85 °C
1 D, 1/2 D, 2 D (750 mW): -10...40 °C
1 D, 1/2 D, 2 D (650 mW): -10...70 °C
1 D, 1/2 D, 2 D (550 mW): -10...85 °C
Storage temperature[°C] [°C]-10...60
ProtectionIP 68

Tests / approvals

ApprovalBVS 10 ATEX E 132 X; IECEx BVS 10.0085 X
ATEX markingI M1 Ex ia I Ma
MTTF[years] [years]969
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]660.2
Housingcylindrical
Dimensions[mm] [mm]Ø 27 / L = 147
Materialsstainless steel (316Ti/1.4571)

Remarks

Pack quantity1 pcs.

Electrical connection

Cable5 m, FEP, Ø 7.5 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PS308A”