Fast delivery within 72 Hours
IFM PQC812
PQC812
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Reliable monitoring of the system pressure in pneumatics and in compressed air systems
Very high overpressure and vacuum resistance
Clearly visible TFT display
Red/green display for clear identification of the acceptable range
With programmable switching output and analogue output
Convenient operation via buttons or parameter setting via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
|---|---|
| Measuring range | -1...10 bar -0.1...1 MPa |
| -1...10 bar | -0.1...1 MPa |
| Process connection | threaded connection G 1/8 internal thread (2x) |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | for industrial applications |
| Media | compressed air; nitrogen (N2) |
| Conditionally suitable for | other media on request |
| Medium temperature[°C] [°C] | 0...60 |
| Min. burst pressure | 30 bar 3 MPa |
| 30 bar | 3 MPa |
| Pressure rating | 20 bar 2 MPa |
| 20 bar | 2 MPa |
| Vacuum resistance | -1000 mbar -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
|---|---|
| Current consumption[mA] [mA] | < 30 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Overvoltage protection | yes; (< 40 V) |
| Power-on delay time[s] [s] | 0.3 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN; (configurable) |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | < 170 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10 / 1...5, invertible; (scalable) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...10 bar -0.1...1 MPa |
|---|---|
| -1...10 bar | -0.1...1 MPa |
| Set point SP | -1...10 bar -0.1...1 MPa |
| Analogue start point | -1...8 bar -0.1...0.8 MPa |
| -1...8 bar | -0.1...0.8 MPa |
| Analogue end point | 1...10 bar 0.1...1 MPa |
| 1...10 bar | 0.1...1 MPa |
| In steps of | 0.01 bar 0.001 MPa |
| 0.01 bar | 0.001 MPa |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5; (turn down 1:1) |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K: turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,5; (turn down 1:1; including linearity, hysteresis and repeatability) |
| Linearity deviation[% of the span] [% of the span] | < ± 0.5 % (limit value setting according to DIN EN IEC 62828-1) turn down 1:1 |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,25; (turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | 0,2; (Turn down 1:1) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | 0,2; (Turn down 1:1) |
Response times
| Response time[ms] [ms] | 6 |
|---|---|
| Damping process value dAP[s] [s] | 0...4 |
| Damping for the analogue output dAA[s] [s] | 0...99.99 |
Software / programming
| Parameter setting options | display can be rotated and switched off; analogue output selectable and scalable; Teach function; simulation function; diagnostic function |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9: 2019-06 |
| Profiles | Smart Sensor - SSP 4.1.1 Measuring and Switching Sensor, 1 channel BLOB Binary Large Object transfer Common - I&D Identification and Diagnosis Extension Quantity detection, switches when value exceeds the setpoint Function Locator Function ProductURI |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Extension | Quantity detection, switches when value exceeds the setpoint |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 0.6 |
| IO-Link resolution pressure[bar] [bar] | 0.001 |
| IO-Link process data (cyclical) | pressure 16 device status 4 SSC1.1 1 SSC1.2 1 |
| pressure | 16 |
| device status | 4 |
| SSC1.1 | 1 |
| SSC1.2 | 1 |
| IO-Link functions (acyclical) | application specific tag; internal temperature; Medium temperature |
| Supported DeviceIDs | default 1580 |
| default | 1580 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
|---|---|
| Storage temperature[°C] [°C] | -25...85 |
| Protection | IP 65 |
Tests / approvals
| EMC | DIN EN 61326-1 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 392 |
| UL approval | UL approval no. J067 |
| UL approval no. | J067 |
| Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical data
| Weight[g] [g] | 52.3 |
|---|---|
| Housing | rectangular |
| Dimensions[mm] [mm] | 37.7 x 30 x 38.6 |
| Materials | PBT; PC; TPE; NBR; FKM; brass; silicon (coated) |
| Materials (wetted parts) | PBT; FKM; brass; silicon (coated) |
| Min. pressure cycles | 50 million |
| Process connection | threaded connection G 1/8 internal thread (2x) |
Displays / operating elements
| Display | Display 1" 128 x 96 pixels switching status 1 x LED, yellow |
|---|---|
| Display 1" | 128 x 96 pixels |
| switching status | 1 x LED, yellow |
| Display unit | bar; MPa; mmHg; kgf/cm² |
Accessories
| Items supplied | head cap screw: 2 x (M3 x 8 mm) |
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connector | 1 x M8; coding: A; Contacts: gold-plated |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM PQC812” Cancel reply

Reviews