Fast delivery within 72 Hours
IFM PP7553
PP7553
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Robust design for use in harsh industrial environments
Two switching outputs, one of which can be configured as diagnostic output
High shock and vibration resistance
Lifespan of more than 100 million pressure cycles
User-friendly communication and parameterisation via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Measuring range | 0...25 bar 0...363 psi 0...2.5 MPa |
| 0...25 bar | 0...363 psi |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Application
| Application | for industrial applications |
|---|---|
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90 |
| Min. burst pressure | 350 bar 5075 psi 35 MPa |
| 350 bar | 5075 psi |
| Pressure rating | 150 bar 2175 psi 15 MPa |
| 150 bar | 2175 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 9.6...36 DC; (communication mode: 18...32) |
|---|---|
| Current consumption[mA] [mA] | < 45 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...25 bar 0...363 psi 0...2.5 MPa |
|---|---|
| 0...25 bar | 0...363 psi |
| Set point SP | 0.2...25 bar 4...362 psi 0.02...2.5 MPa |
| 0.2...25 bar | 4...362 psi |
| Reset point rP | 0.1...24.9 bar 2...360 psi 0.01...2.49 MPa |
| 0.1...24.9 bar | 2...360 psi |
| In steps of | 0.1 bar 2 psi 0.01 MPa |
| 0.1 bar | 2 psi |
| Factory setting | SP1 = 6.3 bar rP1 = 5.8 bar SP2 = 18.8 bar rP2 = 18.3 bar OUT1 = Hno OUT2 = Hno |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Zero-point stabilisation[% of the span] [% of the span] | IO-Link 1,0; (see operating instructions zero-point behaviour) |
| switching output | 1,0 |
| IO-Link | 1,0; (see operating instructions zero-point behaviour) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
|---|---|
| Damping process value dAP in steps[s] [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.0 |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default 5 |
| default | 5 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...85 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
Tests / approvals
| EMC | immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity according to the automotive directive 1995/54/EC / 04/104EG / 05/83/EG absorber chamber test to ISO 11452-2: 80 V/m |
|---|---|
| immunity | according to the automotive directive 1995/54/EC / 04/104EG / 05/83/EG |
| EN 61000-4-2 ESD | 4 kV contact discharge / 15 kV air discharge |
| EN 61000-4-3 HF radiated | 20 V/m |
| EN 61000-4-4 Burst | 4 kV coupling clamp |
| EN 61000-4-5 Surge | 0,5 kV supply / 1 kV signal for DC units |
| EN 61000-4-6 HF conducted | 10 V |
| absorber chamber test to ISO 11452-2: | 80 V/m |
| Shock resistance | DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3 |
| DIN IEC 60068-2-27 / DIN IEC 60068-2-29 | 1000 g |
| DIN EN 61373 | category 2 |
| Vibration resistance | DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2 |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| DIN EN 60068-2-64 | 14 g |
| MTTF[years] [years] | 310 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Railway applications | DIN EN 50155 Klasse T3, C1, S1 |
| DIN EN 50155 | Klasse T3, C1, S1 |
Mechanical data
| Weight[g] [g] | 226.5 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 30 / L = 79.5 |
| Materials | stainless steel (304/1.4301); FKM; EPDM/X; PA |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | operation 2 x LED, green switching status 2 x LED, yellow |
|---|---|
| operation | 2 x LED, green |
| switching status | 2 x LED, yellow |
| Teach function | yes |
Remarks
| Remarks | with reference to UL: "limited voltage" with overcurrent protection in accordance with UL508 |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM PP7553” Cancel reply

Reviews
Clear filtersThere are no reviews yet.