Fast delivery within 72 Hours

IFM PP0522

PP0522

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Robust design for use in harsh industrial environments
Two switching outputs, one of which can be configured as diagnostic output
High shock and vibration resistance
Lifespan of more than 100 million pressure cycles

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range0...100 bar
0...1450 psi
0...10 MPa
0...100 bar0...1450 psi
Process connectionthreaded connection G 1/4 external thread internal thread:M5

Application

Applicationfor industrial applications
Medialiquids and gases
Conditionally suitable foruse in gases at pressures > 25 bar only on request
Medium temperature[°C] [°C]-25...90
Min. burst pressure650 bar
9400 psi
65 MPa
650 bar9400 psi
Pressure rating300 bar
4350 psi
30 MPa
300 bar4350 psi
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]9.6...36 DC; (communication mode: 18...32)
Current consumption[mA] [mA]< 45
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal
Electrical designNPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]170
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...100 bar
0...1450 psi
0...10 MPa
0...100 bar0...1450 psi
Set point SP1...100 bar
20...1450 psi
0.1...10 MPa
1...100 bar20...1450 psi
Reset point rP0.5...99.5 bar
10...1440 psi
0.05...9.95 MPa
0.5...99.5 bar10...1440 psi
In steps of0.5 bar
10 psi
0.05 MPa
0.5 bar10 psi
Factory settingSP1 = 25.0 bar
rP1 = 23.0 bar
SP2 = 75.0 bar
rP2 = 73.0 bar
OUT1 = Hno
OUT2 = Hno

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Zero-point stabilisation[% of the span] [% of the span]1,0; (display, switching output (see operating instructions zero-point behaviour ))
Hysteresis deviation[% of the span] [% of the span]< ± 0,1
Long-term stability[% of the span] [% of the span]< ± 0,1; (per year)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (0...80 °C)

Response times

Response time[ms] [ms]< 3
Damping process value dAP in steps[s] [s]0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500

Operating conditions

Ambient temperature[°C] [°C]-25...85
Storage temperature[°C] [°C]-40...100
ProtectionIP 68; (7 days / 1 m water depth / 0.1 bar)

Tests / approvals

EMCimmunity
EN 61000-6-2
EN 61000-4-2 ESD
4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated
20 V/m
EN 61000-4-4 Burst
4 kV coupling clamp
EN 61000-4-5 Surge
0,5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted
30 V
immunityEN 61000-6-2
EN 61000-4-2 ESD4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated20 V/m
EN 61000-4-4 Burst4 kV coupling clamp
EN 61000-4-5 Surge0,5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted30 V
Shock resistanceDIN IEC 60068-2-27 / DIN IEC 60068-2-29
1000 g
DIN EN 61373
category 3
DIN IEC 60068-2-27 / DIN IEC 60068-2-291000 g
DIN EN 61373category 2
Vibration resistanceDIN IEC 68-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-64
14 g
DIN EN 61373
category 2
DIN IEC 68-2-620 g (10...2000 Hz)
DIN EN 60068-2-6414 g
MTTF[years] [years]309.28
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]224.5
Housingcylindrical
Dimensions[mm] [mm]Ø 30 / L = 79.5
Materialsstainless steel (304/1.4301); FKM; EPDM/X; PA
Materials (wetted parts)stainless steel (303/1.4305); ceramics; FKM
Min. pressure cycles100 million
Process connectionthreaded connection G 1/4 external thread internal thread:M5
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

Displayoperation
2 x LED, green
switching status
2 x LED, yellow
operation2 x LED, green
switching status2 x LED, yellow
Teach functionyes

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PP0522”

Your email address will not be published. Required fields are marked *