Fast delivery within 72 Hours
IFM PP0520
PP0520
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Robust design for use in harsh industrial environments
Two switching outputs, one of which can be configured as diagnostic output
High shock and vibration resistance
Lifespan of more than 100 million pressure cycles
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Measuring range | 0...400 bar 0...5800 psi 0...40 MPa |
| 0...400 bar | 0...5800 psi |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Application
| Application | for industrial applications |
|---|---|
| Media | liquids and gases |
| Conditionally suitable for | use in gases at pressures > 25 bar only on request |
| Medium temperature[°C] [°C] | -25...90 |
| Min. burst pressure | 1000 bar 14500 psi 100 MPa |
| 1000 bar | 14500 psi |
| Pressure rating | 600 bar 8700 psi 60 MPa |
| 600 bar | 8700 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 9.6...36 DC; (communication mode: 18...32) |
|---|---|
| Current consumption[mA] [mA] | < 45 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal |
| Electrical design | NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...400 bar 0...5800 psi 0...40 MPa |
|---|---|
| 0...400 bar | 0...5800 psi |
| Set point SP | 4...400 bar 60...5790 psi 0.4...40 MPa |
| 4...400 bar | 60...5790 psi |
| Reset point rP | 2...398 bar 30...5760 psi 0.2...39.8 MPa |
| 2...398 bar | 30...5760 psi |
| In steps of | 2 bar 30 psi 0.2 MPa |
| 2 bar | 30 psi |
| Factory setting | SP1 = 100 bar rP1 = 92 bar SP2 = 300 bar rP2 = 292 bar OUT1 = Hno OUT2 = Hno |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Zero-point stabilisation[% of the span] [% of the span] | 1,0; (display, switching output (see operating instructions zero-point behaviour )) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
|---|---|
| Damping process value dAP in steps[s] [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...85 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
Tests / approvals
| EMC | immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 30 V |
|---|---|
| immunity | EN 61000-6-2 |
| EN 61000-4-2 ESD | 4 kV contact discharge / 15 kV air discharge |
| EN 61000-4-3 HF radiated | 20 V/m |
| EN 61000-4-4 Burst | 4 kV coupling clamp |
| EN 61000-4-5 Surge | 0,5 kV supply / 1 kV signal for DC units |
| EN 61000-4-6 HF conducted | 30 V |
| Shock resistance | DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3 |
| DIN IEC 60068-2-27 / DIN IEC 60068-2-29 | 1000 g |
| DIN EN 61373 | category 2 |
| Vibration resistance | DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2 |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| DIN EN 60068-2-64 | 14 g |
| MTTF[years] [years] | 309 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 216 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 30 / L = 79.5 |
| Materials | stainless steel (304/1.4301); FKM; EPDM/X; PA |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
| Restrictor element integrated | yes |
Displays / operating elements
| Display | operation 2 x LED, green switching status 2 x LED, yellow |
|---|---|
| operation | 2 x LED, green |
| switching status | 2 x LED, yellow |
| Teach function | yes |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connector | 1 x M12; coding: A |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM PP0520” Cancel reply

Reviews
Clear filtersThere are no reviews yet.