Fast delivery within 72 Hours

IFM PP004E

PP004E

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Suited for use in mobile machines
Two switching outputs, one of which can be configured as diagnostic output
High shock and vibration resistance
Excellent EMC resistance
User-friendly communication and parameterisation via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range-1...10 bar
-14.5...145 psi
-100...1000 kPa
-0.1...1 MPa
-1...10 bar-14.5...145 psi
Process connectionthreaded connection G 1/4 external thread internal thread:M5

Application

Applicationfor mobile applications
Medialiquids and gases
Medium temperature[°C] [°C]-25...90
Min. burst pressure150 bar
2175 psi
15 MPa
150 bar2175 psi
Pressure rating75 bar
1087 psi
7.5 MPa
75 bar1087 psi
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage[V] [V]9.6...36 DC; (communication mode: 18...32)
Current consumption[mA] [mA]< 45
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]170
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-1...10 bar
-14.5...145 psi
-100...1000 kPa
-0.1...1 MPa
-1...10 bar-14.5...145 psi
Set point SP-0.9...10 bar
-13...145 psi
-0.09...1 MPa
-0.9...10 bar-13...145 psi
Reset point rP-0.95...9.95 bar
-14...144 psi
-0.095...0.995 MPa
-0.95...9.95 bar-14...144 psi
In steps of0.05 bar
1 psi
0.005 MPa
0.05 bar1 psi
Factory settingSP1 = 2.50 bar
rP1 = 2.30 bar
SP2 = 7.50 bar
rP2 = 7.30 bar
OUT1 = Hno
OUT2 = Hno

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Zero-point stabilisation[% of the span] [% of the span]IO-Link
1,0; (see operating instructions zero-point behaviour)
switching output, display1,0
IO-Link1,0; (see operating instructions zero-point behaviour)
Hysteresis deviation[% of the span] [% of the span]< ± 0,1
Long-term stability[% of the span] [% of the span]< ± 0,1; (per year)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (0...80 °C)

Response times

Response time[ms] [ms]< 3
Damping process value dAP in steps[s] [s]0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.0
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary2
Min. process cycle time[ms] [ms]2.3
Supported DeviceIDsdefault
6
default6

Operating conditions

Ambient temperature[°C] [°C]-25...85
Storage temperature[°C] [°C]-40...100
ProtectionIP 68; (7 days / 1 m water depth / 0.1 bar)

Tests / approvals

EMCimmunity
EN 61000-6-2
EN 61000-4-2 ESD
4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated
20 V/m
EN 61000-4-4 Burst
4 kV coupling clamp
EN 61000-4-5 Surge
0,5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted
10 V
immunity
ECE R 10, Rev. 5
absorber chamber test to ISO 11452-2:
80 V/m
immunityECE R 10, Rev. 5
EN 61000-4-2 ESD4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated20 V/m
EN 61000-4-4 Burst4 kV coupling clamp
EN 61000-4-5 Surge0,5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted10 V
absorber chamber test to ISO 11452-2:80 V/m
Shock resistanceDIN IEC 60068-2-27 / DIN IEC 60068-2-29
1000 g
DIN EN 61373
category 3
DIN IEC 60068-2-27 / DIN IEC 60068-2-291000 g
DIN EN 61373category 2
Vibration resistanceDIN IEC 68-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-64
14 g
DIN EN 61373
category 2
DIN IEC 68-2-620 g (10...2000 Hz)
DIN EN 60068-2-6414 g
MTTF[years] [years]310
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Railway applicationsDIN EN 50155
Klasse T3, C1, S1
DIN EN 50155Klasse T3, C1, S1

Mechanical data

Weight[g] [g]224
Housingcylindrical
Dimensions[mm] [mm]Ø 30 / L = 79.5
Materialsstainless steel (304/1.4301); FKM; EPDM/X; PA
Materials (wetted parts)stainless steel (303/1.4305); ceramics; FKM
Min. pressure cycles100 million
Process connectionthreaded connection G 1/4 external thread internal thread:M5
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

Displayoperation
2 x LED, green
switching status
2 x LED, yellow
operation2 x LED, green
switching status2 x LED, yellow
Teach functionyes

Remarks

Remarkswith reference to UL: "limited voltage" with overcurrent protection in accordance with UL508
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A