Fast delivery within 72 Hours
IFM PP003E
PP003E
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Suited for use in mobile machines
Two switching outputs, one of which can be configured as diagnostic output
High shock and vibration resistance
Excellent EMC resistance
User-friendly communication and parameterisation via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Measuring range | 0...25 bar 0...363 psi 0...2.5 MPa |
| 0...25 bar | 0...363 psi |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Application
| Application | for mobile applications |
|---|---|
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...90 |
| Min. burst pressure | 350 bar 5075 psi 35 MPa |
| 350 bar | 5075 psi |
| Pressure rating | 150 bar 2175 psi 15 MPa |
| 150 bar | 2175 psi |
| Type of pressure | relative pressure |
Electrical data
| Operating voltage[V] [V] | 9.6...36 DC; (communication mode: 18...32) |
|---|---|
| Current consumption[mA] [mA] | < 45 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...25 bar 0...363 psi 0...2.5 MPa |
|---|---|
| 0...25 bar | 0...363 psi |
| Set point SP | 0.2...25 bar 4...362 psi 0.02...2.5 MPa |
| 0.2...25 bar | 4...362 psi |
| Reset point rP | 0.1...24.9 bar 2...360 psi 0.01...2.49 MPa |
| 0.1...24.9 bar | 2...360 psi |
| In steps of | 0.1 bar 2 psi 0.01 MPa |
| 0.1 bar | 2 psi |
| Factory setting | SP1 = 6.3 bar rP1 = 5.8 bar SP2 = 18.8 bar rP2 = 18.3 bar OUT1 = Hno OUT2 = Hno |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Zero-point stabilisation[% of the span] [% of the span] | IO-Link 1,0; (see operating instructions zero-point behaviour) |
| switching output, display | 1,0 |
| IO-Link | 1,0; (see operating instructions zero-point behaviour) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,1 |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
|---|---|
| Damping process value dAP in steps[s] [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.0 |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default 5 |
| default | 5 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...85 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
Tests / approvals
| EMC | immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity ECE R 10, Rev. 5 absorber chamber test to ISO 11452-2: 80 V/m |
|---|---|
| immunity | ECE R 10, Rev. 5 |
| EN 61000-4-2 ESD | 4 kV contact discharge / 15 kV air discharge |
| EN 61000-4-3 HF radiated | 20 V/m |
| EN 61000-4-4 Burst | 4 kV coupling clamp |
| EN 61000-4-5 Surge | 0,5 kV supply / 1 kV signal for DC units |
| EN 61000-4-6 HF conducted | 10 V |
| absorber chamber test to ISO 11452-2: | 80 V/m |
| Shock resistance | DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3 |
| DIN IEC 60068-2-27 / DIN IEC 60068-2-29 | 1000 g |
| DIN EN 61373 | category 2 |
| Vibration resistance | DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2 |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| DIN EN 60068-2-64 | 14 g |
| MTTF[years] [years] | 310 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Railway applications | DIN EN 50155 Klasse T3, C1, S1 |
| DIN EN 50155 | Klasse T3, C1, S1 |
Mechanical data
| Weight[g] [g] | 223.5 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 30 / L = 79.5 |
| Materials | stainless steel (304/1.4301); FKM; EPDM/X; PA |
| Materials (wetted parts) | stainless steel (303/1.4305); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | operation 2 x LED, green switching status 2 x LED, yellow |
|---|---|
| operation | 2 x LED, green |
| switching status | 2 x LED, yellow |
| Teach function | yes |
Remarks
| Remarks | with reference to UL: "limited voltage" with overcurrent protection in accordance with UL508 |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM PP003E” Cancel reply