IFM PN7599

PN7599

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Two switching outputs, one of them with IO-Link communication interface
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range-1...1 bar
-1000...1000 mbar
-14.5...14.5 psi
-29.4...29.4 inHg
-100...100 kPa
-1...1 bar-1000...1000 mbar
Process connectionthreaded connection G 1/4 external thread internal thread:M5

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-25...80
Min. burst pressure30000 mbar
450 psi
880 inHg
3000 kPa
30000 mbar450 psi
Pressure rating10000 mbar
145 psi
290 inHg
1000 kPa
10000 mbar145 psi
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC[Hz] [Hz]< 170
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-1...1 bar
-1000...1000 mbar
-14.5...14.5 psi
-29.4...29.4 inHg
-100...100 kPa
-1...1 bar-1000...1000 mbar
Set point SP-983...1000 mbar
-14.3...14.5 psi
-29...29.5 inHg
-98...100 kPa
-980...1000 mbar-14.3...14.5 psi
Reset point rP-993...990 mbar
-14.4...14.4 psi
-29.3...29.2 inHg
-99...99 kPa
-990...990 mbar-14.4...14.4 psi
Min. difference between SP and rP10 mbar
0.2 psi
0.3 inHg
1 kPa
10 mbar0.2 psi
In steps of1 mbar
0.1 psi
0.1 inHg
0.1 kPa
-983...1000 mbar-14.3...14.5 psi
-993...990 mbar-14.4...14.4 psi
1 mbar0.1 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,25
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-25...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-25...80 °C)

Response times

Response time[ms] [ms]< 3
Delay time programmable dS, dr[s] [s]0...50

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Process data analogue1
Process data binary2
Supported DeviceIDsFactory setting / CMPT = 2
406
Status_B High Resolution / CMPT = 3
604
Factory setting / CMPT = 2406
Status_B High Resolution / CMPT = 3604
NoteFor further information please see the IODD PDF file under "Downloads"
ProfilesSmart Sensor - SSP 3.1
Measuring Sensor
Common - I&D
Identification and Diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
Min. process cycle time[ms] [ms]3
IO-Link resolution pressure1 mbar
0.0001 MPa
1 mbar0.0001 MPa
IO-Link process data (cyclical)pressure
16
device status
4
binary switching information
2
pressure16
binary switching information2
IO-Link functions (acyclical)application specific tag
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
device status4

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]260
UL approvalUL approval no.
J001
UL approval no.J001
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]259.5
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); ceramics; FKM
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 external thread internal thread:M5
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit
4 x LED, green (bar, psi, kPa, inHg)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit4 x LED, green (bar, psi, kPa, inHg)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated