IFM PN7299
PN7299
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Two switching outputs, one of them with IO-Link communication interface
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Measuring range | -1...1 bar -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa |
| -1...1 bar | -1000...1000 mbar |
| Process connection | threaded connection 1/4" NPT internal thread |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Measuring element | ceramic-capacitive pressure measuring cell |
| Application | for industrial applications |
| Media | liquids and gases |
| Medium temperature[°C] [°C] | -25...80 |
| Min. burst pressure | 30000 mbar 450 psi 880 inHg 3000 kPa |
| 30000 mbar | 450 psi |
| Pressure rating | 10000 mbar 145 psi 290 inHg 1000 kPa |
| 10000 mbar | 145 psi |
| Type of pressure | relative pressure; vacuum |
| MAWP for applications according to CRN | 20 bar 20000 mbar 290 psi 590.59 inHg 2000 kPa |
| 20 bar | 20000 mbar |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
|---|---|
| Current consumption[mA] [mA] | < 35 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.3 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (200 (...60 °C) 250 (...40 °C)) |
| Switching frequency DC[Hz] [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -1...1 bar -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa |
|---|---|
| -1...1 bar | -1000...1000 mbar |
| Set point SP | -983...1000 mbar -14.3...14.5 psi -29...29.5 inHg -98...100 kPa |
| -980...1000 mbar | -14.3...14.5 psi |
| Reset point rP | -993...990 mbar -14.4...14.4 psi -29.3...29.2 inHg -99...99 kPa |
| -990...990 mbar | -14.4...14.4 psi |
| Min. difference between SP and rP | 10 mbar 0.2 psi 0.3 inHg 1 kPa |
| 10 mbar | 0.2 psi |
| In steps of | 1 mbar 0.1 psi 0.1 inHg 1 kPa |
| -983...1000 mbar | -14.3...14.5 psi |
| -993...990 mbar | -14.4...14.4 psi |
| 1 mbar | 0.1 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,25 |
| Long-term stability[% of the span] [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,2; (-0...80 °C) |
Response times
| Response time[ms] [ms] | < 3 |
|---|---|
| Delay time programmable dS, dr[s] [s] | 0...50 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| SIO mode | yes |
| Required master port type | A; (when pin 2 not connected: B) |
| Supported DeviceIDs | Factory setting / CMPT = 2 457 Status_B High Resolution / CMPT = 3 636 |
| Factory setting / CMPT = 2 | 457 |
| Status_B High Resolution / CMPT = 3 | 636 |
| Note | For further information please see the IODD PDF file under "Downloads" |
| Profiles | Smart Sensor - SSP 3.1 Measuring Sensor Common - I&D Identification and Diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| Min. process cycle time[ms] [ms] | 3 |
| IO-Link resolution pressure | 1 mbar 0.001 MPa |
| 1 mbar | 0.001 MPa |
| IO-Link process data (cyclical) | pressure 16 device status 4 binary switching information 2 |
| pressure | 16 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | application specific tag |
| Smart Sensor - SSP 3.1 | Measuring Sensor |
| Common - I&D | Identification and Diagnosis |
| device status | 4 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 260 |
| UL approval | UL approval no. J001 |
| UL approval no. | J001 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 221.5 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 34 / L = 90.7 |
| Materials | stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wetted parts) | stainless steel (316L/1.4404); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Tightening torque[Nm] [Nm] | 2...3 turns after hand-fastening; recommended tightening torque; depends on the lubrication, the seal and the pressure load |
| Process connection | threaded connection 1/4" NPT internal thread |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display | Display unit 4 x LED, green (bar, psi, kPa, inHg) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit |
|---|---|
| Display unit | 4 x LED, green (bar, psi, kPa, inHg) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, red/green 4-digit |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|