Fast delivery within 72 Hours

IFM PN7093

PN7093

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Two switching outputs, one of them with IO-Link communication interface
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range0...25 bar
0...362 psi
0...2.5 MPa
0...25 bar0...362 psi
Process connectionthreaded connection G 1/4 internal thread

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Conditionally suitable forFor gaseous media the application is limited to max. 25 bar.
Medium temperature[°C] [°C]-25...80
Min. burst pressure350 bar
5075 psi
35 MPa
350 bar5075 psi
Pressure rating150 bar
2175 psi
15 MPa
150 bar2175 psi
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC[Hz] [Hz]< 170
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...25 bar
0...362 psi
0...2.5 MPa
0...25 bar0...362 psi
Set point SP0.2...25 bar
3...363 psi
0.02...2.5 MPa
0.2...25 bar3...363 psi
Reset point rP0.1...24.9 bar
1...361 psi
0.01...2.49 MPa
0.1...24.9 bar1...361 psi
Min. difference between SP and rP0.2 bar
2 psi
0.02 MPa
0.2 bar2 psi
In steps of0.1 bar
1 psi
0.01 MPa
0.1 bar1 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,25
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-0...80 °C)

Response times

Response time[ms] [ms]< 3
Delay time programmable dS, dr[s] [s]0...50

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Process data analogue1
Process data binary2
Supported DeviceIDsFactory setting / CMPT = 2
402
Status_B High Resolution / CMPT = 3
600
Factory setting / CMPT = 2402
Status_B High Resolution / CMPT = 3600
NoteFor further information please see the IODD PDF file under "Downloads"
ProfilesSmart Sensor - SSP 3.1
Measuring Sensor
Common - I&D
Identification and Diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
Min. process cycle time[ms] [ms]3
IO-Link resolution pressure0.01 bar
0.001 MPa
0.1 bar0.01 MPa
IO-Link process data (cyclical)pressure
16
device status
4
binary switching information
2
pressure16
binary switching information2
IO-Link functions (acyclical)application specific tag
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
0.01 bar0.001 MPa
device status4

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]260
UL approvalUL approval no.
J001
UL approval no.J001
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]235
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 90.7
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); ceramics; FKM
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 internal thread
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit
3 x LED, green (bar, psi, MPa)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PN7093”

Your email address will not be published. Required fields are marked *