Fast delivery within 72 Hours

IFM PN3592

PN3592

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link
Programmable switching output with IO-Link and analogue output

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range0...100 bar
0...1450 psi
0...10 MPa
0...100 bar0...1450 psi
Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
MediaLiquids
Conditionally suitable foruse in gases at pressures > 25 bar only on request
Medium temperature[°C] [°C]-25...80
Min. burst pressure650 bar
9400 psi
65 MPa
650 bar9400 psi
Pressure rating300 bar
4350 psi
30 MPa
300 bar4350 psi
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC[Hz] [Hz]< 170
Number of analogue outputs1
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...100 bar
0...1450 psi
0...10 MPa
0...100 bar0...1450 psi
Set point SP0.8...100 bar
12...1450 psi
0.08...10 MPa
1...100 bar10...1450 psi
Reset point rP0.3...99.5 bar
5...1443 psi
0.03...9.95 MPa
0.5...99.5 bar5...1445 psi
Min. difference between SP and rP0.5 bar
0.8 psi
0.05 MPa
0.5 bar0.8 psi
In steps of1 bar
1 psi
0.1 MPa
0.8...100 bar12...1450 psi
0.3...99.5 bar5...1443 psi
1 bar1 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,25
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-0...80 °C)

Response times

Response time[ms] [ms]< 3
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...4
Damping for the analogue output dAA[s] [s]0...4
Max. response time analogue output[ms] [ms]3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary1
Supported DeviceIDsFactory setting / CMPT = 2
429
Status_B High Resolution / CMPT = 3
608
Factory setting / CMPT = 2429
Status_B High Resolution / CMPT = 3608
NoteFor further information please see the IODD PDF file under "Downloads"
ProfilesSmart Sensor - SSP 3.1
Measuring Sensor
Common - I&D
Identification and Diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
Min. process cycle time[ms] [ms]3
IO-Link resolution pressure0.05 bar
0.001 MPa
0.1 bar0.01 MPa
IO-Link process data (cyclical)pressure
16
device status
4
binary switching information
1
pressure16
binary switching information1
IO-Link functions (acyclical)application specific tag
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
0.05 bar0.001 MPa
device status4

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]225
UL approvalUL approval no.
J005
UL approval no.J005
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]297
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); Al2O3 (ceramics); FKM
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5
Process connection sealingFKM (DIN EN ISO 1179-2)
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit
3 x LED, green (bar, psi, MPa)
switching status
1 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit3 x LED, green (bar, psi, MPa)
switching status1 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PN3592”

Your email address will not be published. Required fields are marked *