IFM PN2698

PN2698

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Two switching outputs, one of them programmable as IO-Link and one as analogue output
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range-0.0125...0.25 bar
-12.5...250 mbar
-5...100.4 inH2O
-1.25...25 kPa
-127...2549 mmWS
-0.0125...0.25 bar-12.5...250 mbar
Process connectionthreaded connection 1/4" NPT external thread

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-25...80
Min. burst pressure30000 mbar
12000 inH2O
3000 kPa
306000 mmWS
30000 mbar12000 inH2O
Pressure rating10000 mbar
4000 inH2O
1000 kPa
102000 mmWS
10000 mbar4000 inH2O
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure
MAWP for applications according to CRN10 bar
10000 mbar
4000 inH2O
1000 kPa
10 bar10000 mbar

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]< 500
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable 1:5)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable 1:5)
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-0.0125...0.25 bar
-12.5...250 mbar
-5...100.4 inH2O
-1.25...25 kPa
-127...2549 mmWS
-0.0125...0.25 bar-12.5...250 mbar
Analogue start point-12.5...200 mbar
-5...80.2 inH2O
-1.25...20 kPa
-125...2040 mmWS
-12.5...200 mbar-5...80.2 inH2O
Analogue end point37.5...250 mbar
15...100.4 inH2O
3.75...25 kPa
385...2550 mmWS
37.5...250 mbar15...100.4 inH2O
Set point SP-10.9...250 mbar
-4.4...100.4 inH2O
-1.09...25 kPa
-112...2550 mmWS
-11...250 mbar-4.4...100.4 inH2O
Reset point rP-12...249 mbar
-4.8...100 inH2O
-1.2...24.9 kPa
-122...2539 mmWS
-12...249 mbar-4.8...100 inH2O
Min. difference between SP and rP1.1 mbar
0.5 inH2O
0.11 kPa
11 mmWS
1.5 mbar0.6 inH2O
In steps of0.1 mbar
0.1 inH2O
0.01 kPa
1 mmWS
0.5 mbar0.2 inH2O
-10.9...250 mbar-4.4...100.4 inH2O
1.1 mbar0.5 inH2O
0.1 mbar0.1 inH2O

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span] [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< ± 0,2; (-0...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%

Response times

Response time[ms] [ms]< 1.5
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...4
Damping for the analogue output dAA[s] [s]0...4
Max. response time analogue output[ms] [ms]3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Supported DeviceIDsFactory setting / CMPT = 2
476
Status_B High Resolution / CMPT = 3
992
Factory setting / CMPT = 2476
Status_B High Resolution / CMPT = 3992
NoteFor further information please see the IODD PDF file under "Downloads"
ProfilesSmart Sensor - SSP 3.1
Measuring Sensor
Common - I&D
Identification and Diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
Min. process cycle time[ms] [ms]3
IO-Link resolution pressure[mbar] [mbar]0.1
IO-Link process data (cyclical)pressure
16
device status
4
binary switching information
2
pressure16
binary switching information2
IO-Link functions (acyclical)application specific tag
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
device status4

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]145
UL approvalUL approval no.
J012
UL approval no.J012
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]246
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 90.7
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); AI2O3 (96%; ceramics); FKM
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]> 50; (depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection 1/4" NPT external thread
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit
4 x LED, green (mbar, mmWS, kPa, inH2O)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit4 x LED, green (mbar, mmWS, kPa, inH2O)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PN2698”

Your email address will not be published. Required fields are marked *