Fast delivery within 72 Hours

IFM PN2070

PN2070

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Two switching outputs, one of them programmable as IO-Link and one as analogue output
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0...400 bar
0...5800 psi
0...40 MPa
0...400 bar0...5800 psi
Process connectionthreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)

Application

Special featureGold-plated contacts
Measuring elementmetallic thin film cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-25...80
Min. burst pressure1700 bar
24650 psi
170 MPa
1700 bar24650 psi
Pressure rating800 bar
11580 psi
80 MPa
800 bar11580 psi
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]< 500
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable 1:5)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable 1:5)
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...400 bar
0...5800 psi
0...40 MPa
0...400 bar0...5800 psi
Analogue start point0...320 bar
0...4640 psi
0...32 MPa
0...320 bar0...4640 psi
Analogue end point80...400 bar
1160...5800 psi
8...40 MPa
80...400 bar1160...5800 psi
Set point SP2.5...400 bar
37...5802 psi
0.25...40 MPa
2.5...400 bar37...5802 psi
Reset point rP0.9...398.4 bar
13...5778 psi
0.09...39.84 MPa
1...398.5 bar10...5780 psi
Min. difference between SP and rP1.7 bar
24 psi
0.17 MPa
2 bar30 psi
In steps of0.1 bar
1 psi
0.01 MPa
0.5 bar10 psi
0.9...398.4 bar13...5778 psi
1.7 bar24 psi
0.1 bar1 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span] [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,2; (-25...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,2; (-25...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%

Response times

Response time[ms] [ms]< 1.5
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...4
Damping for the analogue output dAA[s] [s]0...4
Max. response time analogue output[ms] [ms]3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Supported DeviceIDsFactory setting / CMPT = 2
459
Status_B High Resolution / CMPT = 3
638
Factory setting / CMPT = 2459
Status_B High Resolution / CMPT = 3638
NoteFor further information please see the IODD PDF file under "Downloads"
ProfilesSmart Sensor - SSP 3.1
Measuring Sensor
Common - I&D
Identification and Diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
Min. process cycle time[ms] [ms]3
IO-Link resolution pressure[bar] [bar]0.2
IO-Link process data (cyclical)pressure
16
device status
4
binary switching information
2
pressure16
binary switching information2
IO-Link functions (acyclical)application specific tag
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
device status4

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]129
UL approvalUL approval no.
J014
UL approval no.J014
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]238.5
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 90.7
Materialsstainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (630/1.4542/17-4 PH)
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit
3 x LED, green (bar, psi, MPa)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM PN2070”

Your email address will not be published. Required fields are marked *