Description

Robust stainless steel design for the requirements of the food and beverage industry
Hygienic, flush design
Resistant to high-pressure cleaning with aggressive cleaning agents
High temperature resistance and high protection rating
Programmable analogue and switching output
Integrated temperature measurement via IO-Link
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range-100...1600 mbar
-1.46...23.2 psi
-40...642.5 inH2O
-10...160 kPa
-100...1600 mbar-1.46...23.2 psi
Process connectionthreaded connection G 1 external thread Aseptoflex Vario

Application

Special featureGold-plated contacts
Applicationflush mountable for the food and beverage industry
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature[°C] [°C]-25...150
Min. burst pressure40000 mbar
580 psi
4000 kPa
40000 mbar580 psi
Pressure rating15000 mbar
215 psi
1500 kPa
15000 mbar215 psi
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure; vacuum
No dead spaceyes
MAWP for applications according to CRN[bar] [bar]1.6

Electrical data

Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]5...45; (430 bei max. Laststrom)
Power-on delay time[s] [s]< 0.5

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20, invertible; (scalable)
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Max. load[Ω] [Ω](Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]125

Measuring/setting range

Measuring range-25...150 °C
-13...302 °F
-100...1600 mbar-1.46...23.2 psi
Set point SP-98...1600 mbar
-1.42...23.21 psi
-39.2...642.3 inH2O
-9.8...160 kPa
-98...1600 mbar-1.42...23.21 psi
Reset point rP-100...1598 mbar
-1.45...23.17 psi
-40.1...641.4 inH2O
-10...159.8 kPa
-100...1598 mbar-1.45...23.17 psi
Analogue start point-100...1272 mbar
-1.45...18.45 psi
-40.1...510.6 inH2O
-10...127.2 kPa
-100...1272 mbar-1.45...18.45 psi
Analogue end point228...1600 mbar
3.31...23.21 psi
91.6...642.3 inH2O
22.8...160 kPa
228...1600 mbar3.31...23.21 psi
Min. difference between SP and rP3 mbar
0.04 psi
1 inH2O
0.3 kPa
3 mbar0.04 psi
In steps of1 mbar
0.01 psi
0.1 inH2O
0.1 kPa
1 mbar0.01 psi
Factory settingSP1 =400 mbar
rP1 = 368 mbar
SP2 = 1200 mbar
rP2 = 1168 mbar
ASP = 0.00 mbar
AEP = 1600 mbar
dAP = 2.00 s
dAA =2.00 s
-25...150 °C-13...302 °F

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation[% of the span] [% of the span]< ± 0,15; (Turn down 1:1)
Zero-point stabilisation[% of the span] [% of the span]IO-Link, analogue output
0,15; (see operating instructions zero-point behaviour)
display, switching output
0,2
IO-Link, analogue output0,15; (see operating instructions zero-point behaviour)
display, switching output0,2
Hysteresis deviation[% of the span] [% of the span]< ± 0,15; (Turn down 1:1)
Long-term stability[% of the span] [% of the span]< ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range-25...15 °C
Characteristics deviation ± 0,05 % of the span / 10 K
15...80 °C
Characteristics deviation
80...150 °C
Characteristics deviation ± 0,1 % of the span / 10 K
-25...15 °CCharacteristics deviation ± 0,05 % of the span / 10 K
15...80 °CCharacteristics deviation
80...150 °CCharacteristics deviation ± 0,1 % of the span / 10 K
Notes on the accuracy / deviationfor further details see section Diagrams and graphs
Accuracy[K] [K]± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability[K] [K]± 0,2
Resolution[K] [K]0.2

Response times

Damping process value dAP[s] [s]0...99.99
Damping for the analogue output dAA[s] [s]0...99.99
Step response time analogue output[ms] [ms]7
Min. response time of switching output (dAP)[ms] [ms]3
Dynamic response T05 / T09[s] [s]< 45 / < 200; (DIN EN 60751 water ; > 0,9 m/s)

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesCommon - I&D
Identification and Diagnosis
Function
Measurement data, high resolution
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, high resolution
SIO modeyes
Required master port typeA
Min. process cycle time[ms] [ms]5.6
IO-Link resolution pressure[mbar] [mbar]0.05
IO-Link resolution temperature[K] [K]0.2
IO-Link process data (cyclical)pressure
32
temperature
32
device status
4
binary switching information
2
pressure32
temperature32
device status4
binary switching information2
IO-Link functions (acyclical)application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter; measuring cell diagnosis
Supported DeviceIDsdefault
1149
default1149

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 67; IP 68; IP 69K

Tests / approvals

EMCDIN EN 61326-1
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]214
UL approvalUL approval no.
J048
File number UL
E174189
UL approval no.J048
File number ULE174189

Mechanical data

Weight[g] [g]357.3
Housingcylindrical
Dimensions[mm] [mm]Ø 50 / L = 107
MaterialsHousing: stainless steel (316L/1.4404); pushbuttons: PBT; sealings: FKM; M12 connector: PEI; Display: PFA; ventilation diaphragm: PTFE
Materials (wetted parts)measuring cell: ceramics (99.9 % Al2O3); Process connection: stainless steel (316L/1.4435) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; Sealing: PTFE
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]35
Process connectionthreaded connection G 1 external thread Aseptoflex Vario

Displays / operating elements

DisplayDisplay unit
LED, green
switching status
LED, yellow
function display
alphanumeric display, 4-digit
measured values
alphanumeric display, 4-digit
Display unitmbar; psi; kPa; inH2O
switching statusLED, yellow
function displayalphanumeric display, 4-digit
measured valuesalphanumeric display, 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection